• Dual‑channel independent control touch screen electrophoresis power supply for laboratory electrophoresis
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Dual‑channel independent control touch screen electrophoresis power supply for laboratory electrophoresis
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.

Touch Screen Dual Control Universal Electrophoresis Power Supply

No.twoEP300
This touch screen dual control electrophoresis power supply adopts 5-inch capacitive touch screen plus keyboard operation, dual-channel independent output supports constant voltage/constant current/constant power. It has automatic parameter calculation, micro-current anti-diffusion and full safety protection, with 5-year free warranty.
$900.00
  • Dual‑channel independent control touch screen electrophoresis power supply for laboratory electrophoresis
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Touch Screen Dual Control Universal Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Product Overview

  • Key Features

  • Parameter

  • Product Details

  • How to Choose

  • Download

  • Packaging & delivery

  • FAQ

  • Get a Quote

  • This dual-control electrophoresis power supply adopts dual-channel independent output design, each channel can be controlled separately. One equipment can replace two electrophoresis power supplies to support two groups of electrophoresis experiments to run independently or simultaneously, saving laboratory procurement costs and desktop placement space.
  • It is equipped with a 5.0-inch large LED liquid crystal touch screen and physical digital keyboard dual operating mode, the data interface can monitor the running state of each channel in real time, and the screen displays voltage, current, power and timing data synchronously to intuitively check the experimental progress.
  • It supports three output modes: constant voltage, constant current and constant power. It is equipped with automatic gel switching for protein electrophoresis, automatic electrical parameter generation, and micro-current maintenance after the experiment, which effectively reduces repeated manual setting operations and sample failure caused by misoperation or delayed gel cutting.
  • Complete safety protection design including overvoltage, electric arc, no-load, load mutation monitoring, overload & short-circuit detection, leakage protection, open circuit alarm, power-off automatic recovery, pause/resume operation. The device can store 10 programmable experimental methods, each method supports up to 2 running steps, suitable for conventional nucleic acid electrophoresis, protein electrophoresis teaching and conventional scientific research experiments in universities, research institutes, testing laboratories.
  • Dual-channel independent output and independent control for single channel, one machine realizes the working performance of two electrophoresis power supplies, reduce laboratory equipment investment and space occupation.
  • 5.0-inch large LED liquid crystal touch screen, matched with digital keyboard input, simple operation, stable and reliable operation.
  • Real-time data display interface to track the working status of two electrophoresis channels at the same time, easy to find abnormal operation.
  • Three output types optional: constant voltage, constant current, constant power, match all conventional electrophoresis experimental requirements.
  • Protein dedicated function: After the concentrated gel electrophoresis is completed, the equipment automatically switches to the separating gel running program, avoid repeated manual parameter setting.
  • Automatic parameter generation function: After setting one fixed constant value, the voltage, current and power remaining two parameters are automatically generated, avoid constant value setting error caused by manual operation.
  • Micro-current function: Automatically switch to micro-current output after electrophoresis timing ends, prevent sample diffusion caused by machine shutdown, and avoid sample over-run damage.
  • Multi-dimensional safety monitoring: overvoltage, electric arc, no-load, load sudden change monitoring; overload, short-circuit monitoring, leakage protection, open circuit audible alarm; power-off automatic recovery, pause and resume function.
  • The liquid crystal display synchronously shows voltage, current, power and timing time, all experimental core parameters are clear at a glance.
  • Support 10 groups of experimental method programmable storage, each experimental method can set 2 segmented running steps, convenient for quick recall of repeated experimental schemes.
Serial Number Parameter Item Technical Specification
1 Single Channel Output Range Voltage: 5–300V; Current: 1–400mA; Power: 1–75W
2 Output Resolution Voltage 1V, Current 1mA, Power 1W
3 Display Mode 5.0-inch oversized LED capacitive touch screen
4 Timing Adjustment Range 1min – 99h59min, stepless adjustable
5 Overall Dimension 350×235×235mm (Length×Width×Height)
6 Net Weight 3.5Kg
  • The two internal channels adopt independent circuit control, parameter adjustment, start or stop of one channel will not affect the stable operation of the other channel, two different electrophoresis experiments can be carried out simultaneously.
  • Touch screen + physical keyboard dual operation design, when the touch screen is polluted by laboratory liquid reagent or high humidity causes sensitivity decline, the physical keyboard can be used for parameter setting to ensure stable operation.
  • The automatic switching program for concentrated gel and separating gel reduces the repetitive operation of laboratory personnel in protein electrophoresis batch experiments, improves the consistency of experimental operation.
  • Micro-current maintenance after the experiment solves the problem of sample band diffusion and over-running caused by cutting the gel later than the scheduled time, no need for long-time on-site waiting after the experiment.
  • When short circuit, electric leakage, overvoltage and other faults occur during operation, the safety circuit will send out an alarm and cut off the output power to protect the electrophoresis tank, gel samples and the internal circuit of the power supply.
  • 10 groups of experimental programs can be stored inside the machine, two-step segmented electrophoresis setting meets the segmented electrophoresis needs of protein pre-electrophoresis and formal electrophoresis, and the stored program can be called directly to shorten the pre-experiment preparation time.
  • Laboratories need two groups of conventional electrophoresis experiments at the same time, choose this dual-channel model, one device replaces two single-channel power supplies, control procurement cost and save bench space.
  • University teaching laboratories for student comparative electrophoresis experiments: two independent channels set different voltage and time parameters to complete the experimental group and control group electrophoresis at one time, improve classroom teaching efficiency.
  • Laboratories mainly carry out conventional vertical protein electrophoresis, low-voltage nucleic acid electrophoresis: 5–300V voltage range fully matches low-pressure protein gel electrophoresis and conventional agarose nucleic acid electrophoresis.
  • The experimental personnel cannot stay for gel cutting after the experiment: the built-in micro-current protection function can avoid sample scrapping caused by delayed gel cutting.
  • The laboratory power supply is unstable and power failure occurs occasionally: power-off automatic recovery function continues the experimental program after power is restored, preventing long-time electrophoresis experiment failure.
  • Need to solidify mature experimental parameters for long-term repeated use: 10 groups of program storage realize one-click calling of mature experimental parameters, suitable for laboratories with standardized experimental operation.
  • Matching supporting equipment: vertical protein electrophoresis tank, conventional horizontal agarose electrophoresis tank, mini vertical electrophoresis tank, applicable to conventional molecular biology electrophoresis supporting equipment.
  • Contact sales staff to obtain the complete electronic technical documents of the equipment for free.
  • Available downloadable documents: operation manual, factory inspection certificate, complete parameter specification, dimension drawing, bidding parameter sheet.
  • All documents are provided in PDF format, convenient for laboratory file filing, project bidding parameter sorting and equipment acceptance verification.
  • Packaging: Export hard carton with integrated thick foam lining, shockproof and anti-collision protection for long-distance transportation.

  • In-stock delivery cycle: 3–10 working days after order confirmation.

  • Standard packing list: electrophoresis power main unit, power cord, two sets of electrode connecting wires, operation manual, factory inspection certificate.

  • Support neutral unbranded packaging and customized outer box printing according to customer requirements

1.Q: Can two channels set different voltage, current and time parameters to run experiments separately?
A: The two channels are controlled independently, each channel can set independent experimental parameters to run different electrophoresis experiments at the same time.
2.Q: Will the device cut off the output completely when the timing is over?
A: It will not cut off power directly, it will enter micro-current output to protect the gel sample.
3.Q: What protection action will the equipment take when the electrophoresis tank is short-circuited?
A: The equipment will trigger an audible alarm and cut off power output to protect the internal circuit of the power supply.
4.Q: Can the stored 10 experimental methods be modified or deleted by users?
A: Users can freely modify, overwrite or delete stored experimental programs according to experimental needs.
5.Q: Can the equipment continue the experiment after sudden power failure and power recovery?
A: With power-off automatic recovery function, it can resume the unfinished electrophoresis experiment after power is restored.
6.Q: Does the whole machine support switching of constant voltage, constant current and constant power modes?
A: The equipment supports three working mode switching, and the two channels follow the main mode setting synchronously.
7.Q: Is the post-experiment micro-current value adjustable manually?
A: The micro-current after the experiment is fixed logic output, no manual adjustment is required.
8.Q: What is the shortest adjustable timing time of the equipment?
A: The minimum timing setting is 1 minute, which meets the demand of short-time pre-electrophoresis experiment.
9.Q: Is the equipment suitable for long-time continuous electrophoresis operation?
A: The internal power circuit has stable heat dissipation, which can meet the continuous operation demand of conventional laboratory batch experiments.
10.Q: Can electrode wires be purchased separately for replacement?
A: Electrode connecting wires are general standard accessories, which can be purchased separately for replacement after aging and damage.
  • Send procurement needs through email, WhatsApp, online consultation and message board.
  • Kindly specify the product model, purchase quantity, delivery address and customized requirements for accurate quotation.
  • The business team will issue a formal quotation including unit price, delivery time and trade terms within 24 working hours.
  • Bulk procurement can enjoy preferential price and priority delivery arrangement.
Applications 应用场景模块

Applications

Applications

Supporting diverse laboratory and industrial environments with practical instrument solutions.

Research Laboratories

Research Laboratories

Conduct SDS-PAGE protein separation, nucleic acid electrophoresis and molecular specimen analysis for life science research..

Universities and Education

Universities & Education

Complete protein & gene electrophoresis experiments for biotech, biology and chemistry course training.

Pharmaceutical and Chemical

Pharmaceutical & Chemical

Analyze target protein, separate biological ingredients and test biopharmaceutical sample purity.

Food Environmental and Industrial Testing

Food, Environmental & Industrial Testing

Identify microbial nucleic acid and detect protein composition in food and environmental samples..

Leave a message
Name *
Email *
Whatsapp/Phone
Message *
Verification Code *
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.