• Benchtop Multi‑Parameter Touch Screen Meter for laboratory water physicochemical analysis
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi‑Parameter Touch Screen Meter for laboratory water physicochemical analysis
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.

Benchtop Multi-Parameter Touch Screen Meter

No.LBPHT100/LBECT100/LBDOT100
The Benchtop Meters Touch screen (Single Parameter) isaimed at laboratories in biotechnology, pharmaceuticals,and education. Its target audience includes researchersand technicians who require precise single-parametermeasurements with intuitive touch screen control forquality control and research applications.
Model:
LBPHT100
LBECT100
LBDOT100
$727.00
  • Description

  • Key Features

  • Parameter

  • Product Details

  • How to Choose

  • Packaging & delivery

  • Download

  • FAQ

  • Get a Quote

This series of single-parameter touch-screen benchtop water analyzers includes 3 independent models: LBPHT100 for pH/ORP only, LBECT100 for conductivity only, LBECT100 for dissolved oxygen only. It fits biotech, pharmaceutical, university education, food, environmental water quality and third-party testing labs for water quality QC, R&D sample screening, purified water production and aquaculture/surface water monitoring requiring only one single testing indicator.
It solves lab drawbacks of high cost of multi-parameter meters with unused redundant functions for single-index testing, complicated small-key operation, tedious calibration and unstable readings affected by temperature, pressure and salinity. Equipped with 7-inch high-resolution touch screen with graphic-text visual navigation for easy operation, it integrates intelligent routines: 1–5 point automatic pH calibration, full-range ATC auto temperature compensation and timed data logger, storing 500 readings per parameter. Data can be exported via flash disk, PC or wireless printer. A flexible probe holder, magnetic stirrer and full original electrodes & calibration consumables are supplied as standard. IP54 protection class with automatic barometric & temperature compensation (DO model adds 0–45ppt manual salinity compensation). Single-parameter dedicated models deliver higher cost performance without redundant functions to cut equipment procurement budget for single-index testing.
  • Dedicated single-parameter design: Separate pH/conductivity/DO models for targeted purchase without redundant unused functions, cutting procurement cost compared with triple-parameter integrated meters for labs only requiring single-index testing.
  • 7-inch high-definition touch screen: Integrated graphic & text operation navigation replaces tiny traditional key screens, enabling new operators to finish calibration, measurement and data export without long learning curve.
  • Full intelligent auto calibration routine: 1–5 point fully automatic pH calibration and single-point conductivity calibration reduce manual steps and human reading error.
  • Multi-dimensional environmental interference compensation: Universal auto temperature & barometric compensation for all models; DO version adds 0–45ppt manual salinity compensation for accurate seawater & high-salinity aquaculture reading correction.
  • Large local data storage: 500 independent stored readings per parameter to avoid accidental data loss during batch sample testing.
  • Triple data export modes: Flash disk local copy, wired PC transmission and on-site wireless printer printout, satisfying both electronic ledger filing and paper original record archiving demands.
  • Complete standard lab accessories: Flexible adjustable probe holder, magnetic stirrer, matched dedicated test electrodes, full set calibration buffers and DO membrane refill consumables (DO model) for immediate out-of-box testing without extra accessory purchase.
  • IP54 protection class: Resist minor bench splashes of reagent and water for extended service life on open lab workstations.
  • Timed automatic data logging: Auto record readings at set intervals without manual supervision, suitable for long-term static water sample monitoring experiments.
Specifications LBPHT100 LBECT100 LBDOT100
Parameter pH/mV.°C √ - -
mV(ORP).°C √ - -
Cond/TDS/Sal./Res.°C - √ -
DO.°C - - √
pH Measurement range (-2.000~20.000)pH √ - -
Resolution 0.01/0.001 √ - -
Accuracy ±0.002pH ±one digit √ - -
Calibration points 1,2,5pts automatic √ - -
ATC range (0.0~100.0)°C/(32.0~212.0)°F √ - -
ORP Measurement range (-1999.9~+1999.9) mV √ - -
Resolution 0.1/1 √ - -
Accuracy ±0.03%F.S ±one digit √ - -
Conductivity Measurement range 0~2000.0mS/cm, Auto-ranging:
0~19.999μS/cm; 20.0~199.9μS/cm;
200~1999μS/cm; 2.00~19.99mS/cm;
20.00~199.9mS/cm;
200.0~2000mS/cm(K=10)
Match test range:0~200mS/cm
TDS:0~100.0g/L (TDS factor adjustable)
Resistivity:5.000Ω·cm~100.0MΩ·cm
Salinity: 0~100ppt
- √ -
Calibration points one point - √ -
Resolution 0.001 - √ -
ATC range (0.0~50.0)°C/(32.0~122.0)°F - √ -
Accuracy ±0.5%F.S ±one digit - √ -
DO Measurement range (0.00~20.00)mg/L - - √
Accuracy ±0.30 mg/L - - √
DO saturation (0.0~200.0)% - - √
Automatic barometric pressure compensation (0~200.0)kPa - - √
Automatic temperature compensation (0.0~50.0)°C/(32.0~122.0)°F - - √
Manual salinity compensation 0~45ppt - - √
Temperature Measurement range (0.0~100.0)°C/(32.0~212.0)°F √ √ √
Accuracy ±0.2°C √ √ √
Others Data export Flash disk/PC/Printer √ √ √
Power supply DC12V √ √ √
Test kit Meter Meter √ √ √
Glass refillable combination pH probe D201G √ - -
Stainless-steel temperature probe DTEMP-01 √ - -
Glass ATC conductivity probe DCON201TG, K=1.0 - √ -
Polarographic DO probe DD001-2M - - √
pH buffer solution: pH4.00/7.00/10.01, 50mL, one for each √ - -
Standard Cond solution: 84uS/1413uS/12.88mS/cm, 50mL, one for each - √ -
Membrane refill solution: DDOS-01, 30mL, 1btl - - √
Membrane sensor caps DDosc: 3pcs/group, 1pkg - - √
PC cable:1pc √ √ √
  • Model Matching Selection: LBPHT100 for pH/ORP single test; LBECT100 (Cond) for conductivity/TDS/salinity only; LBECT100 (DO) for water dissolved oxygen single measurement.
  • Probe Assembly: Mount matched dedicated electrode on flexible height-adjustable holder, connect to meter port, place magnetic stir bar inside sample beaker for homogenization.
  • Auto Calibration Setup: Enter calibration program via touch screen, immerse probe into supplied calibration buffer; meter finishes 1–5 point pH or single-point conductivity calibration automatically; input sample salinity value for DO model before measurement to activate pressure & temperature compensation.
  • Sample Measurement & Storage: Submerge probe into water sample; the unit automatically detects ambient temperature & pressure to offset interference values, one-click store stable readings within 500 local storage capacity.
  • Data Export & Archiving: After all tests, export all archived readings via flash disk, PC cable or wireless printer to sort lab reports and project original data ledgers.
  • Maintenance & Storage: Rinse probes after testing, replace DO membrane caps & refill solution as needed for DO model, fold holder and stirrer, wipe meter surface and store dust-free.

Key Factors to Help You Pick the Right Model

  1. Select model by single daily test indicator
    pH & ORP testing (reagents, buffer, cell culture medium): LBPHT100 with refillable glass pH combination probe and max 5-point high-precision calibration;
    Dedicated purified/deionized water conductivity/TDS/salinity QC: LBECT100 (Cond), simplified single-parameter unit without redundant functions for lower budget;
    Independent dissolved oxygen monitoring for surface water, aquaculture & waste water: LBECT100 (DO) with polarographic probe and 0–45ppt salinity compensation for high-salinity seawater samples.
  2. Lab procurement budget control
    Single-index testing does not require triple-parameter integrated meter; dedicated single-parameter model eliminates idle redundant functions, full set electrodes & calibration consumables included out of box to cut total procurement cost.
  3. Calibration precision demand
    High-precision R&D & standard reagent calibration: Choose LBPHT100 supporting 1–5 multi-point automatic pH calibration for superior data repeatability;
    Basic routine screening & student teaching: All three models feature auto calibration to meet standard test accuracy.
  4. Data archiving & export demand
    Long-term PC raw data storage: Standard wired PC data cable transmission; on-site hard-copy records: optional wireless printer; short-term local archive: flash disk copy.
  5. Sample environmental interference demand
    Seawater & high-salinity aquaculture DO test only: LBECT100 (DO) supports manual salinity compensation to eliminate reading deviation caused by salt content; all models provide universal auto temperature & barometric compensation for variable altitude & temperature samples.

Model Matching Application Scenarios

LBPHT100 (pH/ORP Single Parameter): Single pH touch screen meter, ideal for university basic teaching, pharmaceutical reagent pH QC and biopharmaceutical cell culture medium calibration with 5-point high-accuracy calibration.
LBECT100 (Conductivity Single Parameter): Dedicated conductivity tester for purified water, deionized water and food raw material TDS/salinity testing, a cost-effective option for small basic labs.
LBECT100 (DO Single Parameter): Single dissolved oxygen benchtop meter for aquaculture farms, environmental monitoring stations and waste water plants to independently monitor water oxygen content with correction function for high-salinity seawater samples.
Target Buyers: University education labs, biopharmaceutical research institutes, pharmaceutical & chemical QC labs, food testing facilities, environmental water monitoring stations, industrial pure water treatment QC labs.
  • Shockproof export packaging: Thick rigid export carton with integrated shock-absorbing foam insert separating main unit, glass electrodes and calibration liquid bottles to prevent breakage & extrusion during long sea/land transportation; bulk orders can upgrade to solid wooden case packaging.
  • Full set package contents: Touch screen benchtop meter main unit, matched full dedicated test electrodes, stainless steel temperature probe (pH model), magnetic stirrer, DF flexible height-adjustable probe holder, PC data cable, complete matched calibration buffer, DO membrane refill solution & sensor caps (DO model), DC12V power adapter, operation manual, factory quality certificate.
  • Reference package dimension & weight: Single set outer carton size 42×35×28cm, gross weight 4.2kg per unit.
  • Lead time: In-stock standard models ship within 3–10 working days; custom color & special electrode specification orders take 15–30 working days.
  • Logistics options: Sea freight, air freight and global door-to-door courier available for bulk complete overseas lab equipment export orders.

Selling Units

Single item

Package size perbatch

60*43*13cm

Gross weight perbatch

3.1kg

 


Name Qty. (DPH100T) Qty. (DEC100T) Qty. (DDO100T)
Main unit 1 1 1
pH composite electrode 1 - -
Conductivity electrode - 1 -
Dissolved oxygen electrode - - 1
Electrode stand 1 1 1
pH calibration solutions (4.00/6.86/9.18) 3 bottles - -
Conductivity calibration solution - 3 bottles -
Dissolved oxygen zero solution - - 1 bottle
Power adapter 1 1 1
Operating Manual 1 1 1
Certificate of Quality 1 1 1
Contact customer service to receive full documents: integrated complete technical datasheet, equipment operation manual, product drawings, brochure and factory test report for lab filing and water quality testing tender submission.

  • What parameters can LBPHT100 / LBECT100(Conductivity) / LBECT100(DO) test respectively?
    LBPHT100: pH, ORP, Temperature
    LBECT100(Conductivity): Conductivity, TDS, Salinity, Resistivity, Temperature
    LBECT100(DO): Dissolved Oxygen DO, Temperature
  • Screen specification and operation difference vs button benchtop meters?
    7-inch HD touch color screen with graphic-text navigation full touch operation without physical buttons, visual menu for more intuitive & simple operation.
  • Maximum auto calibration points for pH channel and accuracy index?
    Supports auto 1~5-point gradient calibration; pH range -2.000~20.000pH, accuracy ±0.002pH ±1 digit.
  • Maximum single parameter data storage and data export modes?
    500 readings stored independently per parameter; export via flash disk, PC linkage transmission or optional wireless printer.
  • IP rating and power supply mode?
    IP54 dustproof & waterproof bench protection; uniform external DC12V power adapter, no built-in rechargeable lithium battery.
  • Does all series have built-in magnetic stirrer, what probe holder as standard?
    All models integrate magnetic stirring unit; DF01 flexible height-adjustable probe holder supplied as standard.
  • Matching original glass probe for each model?
    LBPHT100: D201G refillable glass pH combination electrode + DTEMP-01 stainless steel temp probe;
    LBECT100(Conductivity): DCON201TG glass ATC conductivity probe;
    LBECT100(DO): DDO001-2M polarographic DO probe with 2m cable.
  • What triple environmental compensation functions for DO model?
    Auto barometric compensation 0~200kPa, auto temperature compensation 0~50℃, manual salinity compensation 0~45ppt.
  • Temperature measurement range, accuracy and ATC function for all series?
    Temp range 0~100℃, accuracy ±0.2℃; pH ATC range 0~100℃, conductivity & DO ATC range 0~50℃.
  • What standard calibration reagents & consumables are factory standard for each model?
    LBPHT100: pH buffer 4.00/7.00/10.01 50mL;
    LBECT100(Conductivity): 84μS/1413μS/12.88mS/cm conductivity standards;
    LBECT100(DO): DO membrane refill DDOS-01 & sensor caps DDOSC.
  • Is PC communication cable standard supplied, what is its function?
    PC cable uniformly equipped for all series; used for linkage between benchtop meter and PC to transmit bulk stored experimental data.
  • Conductivity calibration rule, range and TDS function?
    1-point auto calibration for conductivity; auto-ranging 0~2000.0mS/cm, TDS conversion factor can be manually customized.
  • DO measurement range, accuracy and saturation range?
    DO range 0.00~20.00mg/L, accuracy ±0.30mg/L, saturation range 0~200.0%.
  • Core advantages of touch benchtop meters vs portable pocket testers?
    7-inch large touch visual screen, built-in magnetic stirrer, 5-point high-precision pH calibration, 500-group large storage, 24h continuous DC stabilized power supply, high-precision glass research probe, triple data export modes, more suitable for static precise research experiments in labs.
  • Advantages of glass pH electrode vs ordinary plastic pH probe?
    Refillable glass combination electrode has better corrosion resistance & faster response, supports 5-point ultra-high precision calibration, fit for long-term measurement of high-purity & corrosive research samples.
  • Main applicable lab industry scenarios?
    Biopharmaceutical R&D labs, university chemistry/environment/aquaculture teaching labs, third-party water testing institutes, fine chemical, fermentation engineering and ultrapure water R&D labs
  • Send required model, order quantity and destination country to receive tiered bulk discount quotation
  • Free customized single-index water testing matching scheme & official PI issued within 24 hours
  • Exclusive discounted pricing available for bulk procurement from universities, research institutes and environmental third-party testing labs
  • Benchtop Multi‑Parameter Touch Screen Meter for laboratory water physicochemical analysis
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
Applications 应用场景模块

Applications

Applications

Supporting diverse laboratory and industrial environments with practical instrument solutions.

Research Laboratories

Research Laboratories

Suitable for advanced academic research. Our pH meters, water testers and electrochemical analyzers support material, environmental and biochemical research. High-precision electrochemical testing delivers reliable data for frontier studies and long-term experiments.

Universities and Education

Universities & Education

Designed for teaching and student training. These electrochemical instruments are standard for chemistry, environmental and biology labs, demonstrating electrochemical principles and water testing logic in class experiments.

Pharmaceutical and Chemical

Pharmaceutical & Chemical

For pharmaceutical and fine chemical production. Electrochemical gear precisely tracks pH, ion activity and electrolyte features of raw materials, intermediates and finished liquids for full-process quality control..

Food Environmental and Industrial Testing

Food, Environmental & Industrial Testing

For third-party labs and daily industrial monitoring. Our electrochemical devices quickly quantify pH, dissolved.

Leave a message
Name *
Email *
Whatsapp/Phone
Message *
Verification Code *
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.