• Benchtop Multi‑Parameter Touch Screen Meter for lab water quality analysis test
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi‑Parameter Touch Screen Meter for lab water quality analysis test
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.

Benchtop Multi-Parameter Touch Screen Meter

No.LBPC-T100/LBPD-T100/LBCD-T100/LBPCD-T100
The Benchtop Meters Touch screen (Multi Parameter) isaimed at laboratories in biotechnology, pharmaceuticals,and education. Its target audience includes researchersand technicians who require precise multi-parametermeasurements with intuitive touch screen control forquality control and research applications.
Model:
LBPC-T100
LBPD-T100
LBCD-T100
LBPCD-T100
$898.80
  • Description

  • Key Features

  • Parameter

  • Product Details

  • How to Choose

  • Packaging & delivery

  • Download

  • FAQ

  • Get a Quote

This series of benchtop touch-screen multi-parameter water analyzers has 4 models, supporting pH/conductivity, pH/dissolved oxygen, single conductivity, simultaneous pH/conductivity/dissolved oxygen measurement respectively. It fits biotech, pharmaceutical, university education, food, environmental water quality and third-party testing labs for water quality QC, R&D sample test and environmental water monitoring.
It optimizes drawbacks of traditional benchtop meters such as tiny display, complicated operation, separate instruments for multi-parameter test, tedious calibration, inconvenient data export and unstable readings affected by temperature, pressure and salinity. Equipped with 7-inch high-resolution touch screen with graphic-text navigation, it integrates intelligent functions: auto calibration, multi-dimensional automatic compensation and timed data logger. It can store 500 readings per parameter and export data via flash disk, PC or wireless printer. Matching flexible probe holder, magnetic stirrer and complete standard calibration solutions & probes are included. IP54 protection class eliminates environmental interference via automatic temperature, barometric pressure and salinity compensation to guarantee stable test accuracy. It covers single/dual/triple water parameter test in one unit to cut procurement cost of multiple separate devices.
  • 7-inch high-definition touch screen: Visual graphic-text navigation eliminates complicated manual operation of small-key traditional meters, easy for new operators.
  • Optional multi-parameter models: 4 versions for separate pH/conductivity, pH/DO, single conductivity or simultaneous triple-parameter test to match lab test items without redundant functions.
  • Full-range automatic compensation: Auto temperature & barometric pressure compensation for all models, manual salinity compensation for DO versions, removing environmental interference of temperature, pressure and salinity for better data repeatability.
  • Intelligent auto calibration routine: 1–5 points automatic pH calibration and single-point conductivity calibration reduce manual operation error.
  • Large local data storage: 500 independent stored readings per parameter to avoid accidental data loss during long-term experiments.
  • Multi-mode data export: Data transfer via flash disk, wired PC and wireless printer for fast lab report archiving and tender data submission.
  • Complete standard lab accessories: Flexible adjustable probe holder and magnetic stirrer included to homogenize water samples evenly without extra separate purchase.
  • IP54 protection class: Resist minor splashes of water and reagents on lab bench for longer service life.
  • Full set of matched probes & consumables supplied: Complete pH, conductivity and DO probes with calibration buffer, membrane caps and refill solution included for immediate out-of-box testing.
Specifications LBPC-T100 LBPD-T100 LBCD-T100 LBPCD-T100
Parameter pH/mV.°C √ √ - √
mV(ORP).°C √ √ - √
Cond/TDS/Sal./Res.°C √ - √ √
DO.°C - √ √ √
pH Measurement range (-2.000~20.000)pH √ √ - √
Resolution 0.01/0.001 √ √ - √
Accuracy ±0.002pH ±one digit √ √ - √
Calibration points 1,2,5pts automatic √ √ - √
ATC range (0.0~100.0)°C/(32.0~212.0)°F √ √ - √
ORP Measurement range (-1999.9~+1999.9) mV √ √ - √
Resolution 0.1/1 √ √ - √
Accuracy ±0.03%F.S ±one digit √ √ - √
Conductivity Measurement range 0~2000.0mS/cm, Auto-ranging:
0~19.999μS/cm; 20.0~199.9μS/cm;
200~1999μS/cm; 2.00~19.99mS/cm;
20.00~199.9mS/cm;
200.0~2000mS/cm(K=10)
Match test range:0~200mS/cm
TDS:0~100.0g/L (TDS factor adjustable)
Resistivity:5.000Ω·cm~100.0MΩ·cm
Salinity: 0~100ppt
√ - √ √
Calibration points one point √ - √ √
Resolution 0.001 √ - √ √
ATC range (0.0~50.0)°C/(32.0~122.0)°F √ - √ √
Accuracy ±0.5%F.S ±one digit √ - √ √
DO Measurement range (0.00~20.00)mg/L - √ √ √
Accuracy ±0.30 mg/L - √ √ √
DO saturation (0.0~200.0)% - √ √ √
Automatic barometric pressure compensation (0~200.0)kPa - √ √ √
Automatic temperature compensation (0.0~50.0)°C/(32.0~122.0)°F - √ √ √
Manual salinity compensation 0~45ppt - √ √ √
Temperature Measurement range (0.0~100.0)°C/(32.0~212.0)°F √ √ √ √
Accuracy ±0.2°C √ √ √ √
Others Data export Flash disk/PC/Printer √ √ √ √
Power supply DC12V √ √ √ √
Test kit Meter Meter √ √ √ √
Glass refillable combination pH probe D201G √ √ - √
Stainless-steel temperature probe DTEMP-01 √ √ - √
Glass ATC conductivity probe DCON201TG, K=1.0 √ - √ √
Polarographic DO probe DD001-2M - √ √ √
pH buffer solution: pH4.00/7.00/10.01, 50mL, one for each √ √ - √
Standard Cond solution: 84uS/1413uS/12.88mS/cm, 50mL, one for each √ - √ √
Membrane refill solution: DDOS-01, 30mL, 1btl - √ √ √
Membrane sensor caps DDosc: 3pcs/group, 1pkg - √ √ √
PC cable:1pc √ √ √ √
  • Model Matching: Select model based on regular test items; LBPC-T100 for pH+conductivity; LBPD-T100 for pH+DO; LBCD-T100 for single conductivity; LBPCD-T100 for simultaneous three-parameter test.
  • Probe Assembly: Install matched probe on flexible holder, connect to meter interface, place magnetic stir bar into sample beaker.
  • Auto Calibration: Enter calibration program on touch screen, immerse probe into supplied calibration buffer; meter finishes 1–5 point pH or single-point conductivity calibration automatically; set barometric & salinity compensation for DO models.
  • Sample Measurement: Immerse probe into water sample, turn on magnetic stirrer for homogenization. The unit automatically detects temperature & pressure to compensate interference and display real-time readings on screen.
  • Data Storage & Export: One-click local storage for each reading; export all archived data via flash disk, PC or wireless printer after experiment for lab report sorting.
  • Maintenance & Storage: Rinse probes after testing, replace DO membrane caps & refill solution consumables, fold holder and stirrer, wipe meter surface and store dust-free.
  1. Select model by daily test parameters
    Only pH & conductivity test (pure water, reagent): LBPC-T100 supplied with pH glass probe & conductivity electrode;
    pH & dissolved oxygen test (surface water, aquaculture water): LBPD-T100 with pH electrode & polarographic DO probe;
    Single conductivity/TDS/salinity test (purified water): LBCD-T100 simplified single-parameter unit without redundant accessories;
    R&D & third-party labs requiring simultaneous pH+conductivity+DO test: LBPCD-T100 three-in-one meter eliminates switching multiple instruments to boost batch sample efficiency.
  2. Select compensation function by water sample type
    Seawater & high-salinity aquaculture water: Choose DO-equipped models with manual salinity compensation to eliminate reading deviation caused by salt content;
    Outdoor & variable altitude water monitoring: All models support automatic barometric compensation without manual altitude input;
    High/low temperature reagent & waste water: Universal automatic temperature compensation maintains stable accuracy under extreme temperature.
  3. Data archiving demand
    Hard-copy records: Optional wireless printer for on-site reading printout;
    Electronic ledger & tender application: Flash disk / PC export for permanent digital data storage.
  4. Working environment protection demand
    Open lab bench with frequent reagent operation: IP54 protected body resists minor liquid splashes to cut maintenance cost.
  5. Budget & consumable cost control
    Complete probes, calibration buffer, membrane caps and refill solution included for immediate out-of-box use, avoiding separate multi-time accessory procurement.

Model Matching Scenarios

LBPC-T100: Dual parameter pH+conductivity benchtop meter, ideal for university teaching, purified water quality and pharmaceutical reagent QC.
LBPD-T100: pH+DO dual parameter meter for surface water, aquaculture and environmental waste water simultaneous monitoring.
LBCD-T100: Single conductivity meter dedicated to pure water, deionized water and food raw material conductivity/TDS/salinity test.
LBPCD-T100: Three-parameter integrated meter for third-party testing and biopharmaceutical R&D labs to finish three indicators for batch samples at once and save testing time.
Target Buyers: University education labs, biopharmaceutical research institutes, pharmaceutical & chemical QC labs, food testing facilities, environmental water monitoring institutions, industrial water treatment QC labs.
  • Shockproof packaging: Thick anti-collision carton with custom foam compartment separating main unit, glass probes and calibration bottles to prevent breakage and extrusion damage during transit.
  • Standard packing list: Benchtop meter main unit, matched complete test probes, magnetic stirrer, flexible probe holder, PC data cable, matched calibration buffer, DO membrane caps & refill solution (for DO-integrated models).
  • Lead time: In-stock standard models shipped within 3–10 working days; custom accessory orders take 15–30 working days.
  • Logistics options: Sea freight, air freight and global door-to-door courier available for bulk lab equipment overseas orders.
  • Outer package: Full set packed per unit with separated fixed accessories to reduce total shipping cost for bulk procurement.

Selling Units

Single item

Package size perbatch

60*43*13cm

Gross weight perbatch

3.1kg

 


Name Qty. (DPD100T) Qty. (DPC100T) Qty. (DCD100T) Qty. (DPCD100T)
Main unit 1 1 1 1
pH composite electrode 1 1 - 1
Conductivity electrode - 1 1 1
Dissolved oxygen electrode - - - 1
Electrode stand 1 1 1 1
pH calibration solutions (4.00/6.86/9.18) 3 bottles 3 bottles - 3 bottles
Conductivity calibration solution - 3 bottles 3 bottles 3 bottles
Dissolved oxygen zero solution - - - 1 bottle
Power adapter 1 1 1 1
Operating Manual 1 1 1 1
Certificate of Quality 1 1 1 1
Contact us to get full documents: complete technical datasheet, operation manual, equipment drawings and brochure for lab filing and testing tender submission

  • What parameters do LBPC-T100 / LBPD-T100 / LBCD-T100 / LBPCD-T100 test respectively?
    LBPC-T100: pH, ORP, Conductivity, TDS, Salinity, Resistivity, Temperature
    LBPD-T100: pH, ORP, Dissolved Oxygen DO, Temperature
    LBCD-T100: Conductivity, TDS, Salinity, Resistivity, DO, Temperature
    LBPCD-T100: pH, ORP, full conductivity series, DO, Temperature, support simultaneous three-parameter screen display
  • Screen specification & operation mode? Exclusive screen function of LBPCD-T100?
    7-inch HD touch color screen with full touch graphic operation; LBPCD-T100 can display pH, conductivity and DO data simultaneously.
  • Maximum auto calibration points for pH channel and accuracy index?
    Supports auto 1~5-point gradient calibration; pH range -2.000~20.000pH, accuracy ±0.002pH ±1 digit.
  • Maximum single parameter storage and available data export channels?
    Up to 500 readings stored independently per parameter; export via flash disk, PC linkage transmission or optional wireless printer, PC communication cable supplied as factory standard.
  • IP rating and power supply mode?
    IP54 bench dustproof & waterproof protection; uniform external DC12V power adapter, no built-in rechargeable battery.
  • Does all series integrate magnetic stirrer, standard holder & communication accessory?
    All models have built-in magnetic stirring unit; DF01 adjustable probe holder and PC communication cable are standard.
  • Matching original glass probe for each model?
    LBPC-T100: D201G refillable pH combination electrode + DTEMP-01 stainless steel temp probe + DCON201TG conductivity probe;
    LBPD-T100: D201G pH electrode + DTEMP-01 temp probe + 2m DDO001-2M DO probe;
    LBCD-T100: DCON201TG glass conductivity probe + DDO001-2M DO probe;
    LBPCD-T100: Complete set of pH, conductivity and DO glass probes.
  • What triple environmental compensation functions for DO model?
    Auto barometric compensation (0~200kPa), auto temperature compensation (0~50℃), manual salinity compensation (0~45ppt).
  • Temperature measurement range, accuracy and ATC range for each channel?
    Temp range 0~100℃, accuracy ±0.2℃; pH ATC range 0~100℃, conductivity & DO ATC range 0~50℃.
  • Standard calibration consumables factory supplied for each model?
    LBPC-T100: pH buffer pH4/7/10, full set conductivity standards;
    LBPD-T100: pH buffer, DO membrane refill liquid, DO sensor caps;
    LBCD-T100: Conductivity standards, full DO membrane consumables;
    LBPCD-T100: Complete set pH, conductivity and DO calibration consumables.
  • Function of PC communication cable, is it factory standard?
    PC cable is standard supplied; used for linkage between benchtop meter and PC to export bulk stored experimental data.
  • Conductivity calibration rule, range and TDS function?
    1-point auto calibration for conductivity; auto-ranging 0~2000.0mS/cm, TDS conversion factor can be manually customized.
  • DO measurement range, accuracy and saturation range?
    DO range 0.00~20.00mg/L, accuracy ±0.30mg/L, saturation range 0~200.0%.
  • Core advantages of touch benchtop multi-parameter meters vs portable pocket testers?
    7-inch large touch visual screen, built-in magnetic stirrer, 5-point research-grade pH calibration, large 500-group storage, PC linkage export, 24h continuous DC power supply, high-precision glass research probe, triple data export modes, more suitable for static precise research lab experiments.
  • Does polarographic DO probe require regular membrane consumable replacement?
    Yes, LBPD-T100/LBCD-T100/LBPCD-T100 are all supplied with DO membrane liquid and sensor caps, regular replacement is required to guarantee DO measurement precision.
  • Core applicable lab industries?
    Biopharmaceutical R&D labs, university chemistry/aquaculture/environment teaching labs, third-party water testing institutes, fine chemical, fermentation engineering, ultrapure water & marine environmental research labs.

Send required model, order quantity and destination country to get tiered bulk discount pricing
Free customized testing matching scheme & official PI issued within 24 hours
Special discounted rates for universities, research institutes and third-party testing labs
  • Benchtop Multi‑Parameter Touch Screen Meter for lab water quality analysis test
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
  • Benchtop Multi-Parameter Touch Screen MeterIlabcarta Technology Co., Ltd.
Applications 应用场景模块

Applications

Applications

Supporting diverse laboratory and industrial environments with practical instrument solutions.

Research Laboratories

Research Laboratories

Focus on advanced academic research scenarios. Our pH meters, water quality testers and electrochemical analyzers support material electrochemistry, environmental mechanism and biochemistry research. High-precision electrochemical index testing provides reliable data for frontier laboratory research and long-term experimental analysis..

Universities and Education

Universities & Education

Specially matched for school teaching and student training. This series of electrochemical testing instruments is the standard configuration of chemistry, environmental science and biology teaching labs, used for classroom demonstration experiments and undergraduate practical training to intuitively display electrochemical reaction principles and water quality detection logic.

Pharmaceutical and Chemical

Pharmaceutical & Chemical

Targeted at pharmaceutical manufacturing and fine chemical production links. Electrochemical analytical equipment accurately monitors pH value, ion activity and electrolyte properties of raw materials, intermediate liquid and finished pharmaceutical solutions, realizing full-cycle quality inspection for drug synthesis and chemical formulation.

Food Environmental and Industrial Testing

Food, Environmental & Industrial Testing

Dedicated to third-party inspection and industrial routine monitoring. The electrochemical testing lineup conducts rapid quantitative detection of pH, dissolved oxygen and heavy metal ions in food, surface water, factory wastewater and industrial raw materials, meeting daily laboratory quality control and compliance verification requirements..

Leave a message
Name *
Email *
Whatsapp/Phone
Message *
Verification Code *
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.