• Dual‑channel general‑purpose touch screen electrophoresis power supply for laboratory experiments
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Dual‑channel general‑purpose touch screen electrophoresis power supply for laboratory experiments
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.

Benchtop Dual Control Universal Laboratory Electrophoresis Power Supply

No.two-EP600
Benchtop dual control universal laboratory electrophoresis power supply adopts compact desktop structure to save bench space, universal compatibility and dual-channel design for teaching, research and inspection laboratory conventional electrophoresis work.
$1297.00
  • Dual‑channel general‑purpose touch screen electrophoresis power supply for laboratory experiments
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Benchtop Dual Control Universal Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Product Overview

  • Key Features

  • Parameter

  • Product Details

  • How to Choose

  • Download

  • Packaging & delivery

  • FAQ

  • Get a Quote

  • This dual-control general electrophoresis power supply adopts dual-channel independent control output design. One power supply can replace two single-channel power supplies, supporting two groups of electrophoresis experiments to operate independently or synchronously, which effectively reduces laboratory procurement cost and saves bench layout space.
  • Equipped with a 5.0-inch large LED capacitive touch screen and digital keyboard dual-operation structure, the real-time data interface monitors the electrophoresis status of each channel. The screen synchronously displays voltage, current, power and timing data to clearly observe the whole experimental progress.
  • Three output modes of constant voltage, constant current and constant power are available. It is equipped with automatic gel switching function for protein electrophoresis, intelligent automatic parameter generation function and post-experiment micro-current protection function, which greatly reduces tedious manual operations and the risk of sample scrapping caused by operational errors.
  • It has comprehensive safety monitoring functions such as overvoltage, electric arc, no-load, load mutation, overload short circuit, electric leakage protection and open circuit alarm, as well as power-off automatic recovery, pause and resume functions. It can store 10 sets of experimental programs, and each program supports up to 2 segmented steps. It is suitable for various nucleic acid and protein electrophoresis experiments in university teaching laboratories, scientific research institutes, pharmaceutical and chemical enterprises, food and environmental testing laboratories.
  • Dual-channel output with independent control for each channel, one machine achieves the working capacity of two electrophoresis power supplies, cutting laboratory equipment cost and layout space occupation.
  • 5.0-inch oversized LED capacitive touch screen, matched with digital physical keyboard input, operation is convenient, stable and reliable, adapting to diverse laboratory operating environments.
  • Dedicated real-time data interface to synchronously track the operating status of two channels, realizing rapid discovery and disposal of experimental abnormal conditions.
  • Three mainstream output modes including constant voltage, constant current and constant power cover all working conditions of conventional gel electrophoresis experiments.
  • Specialized protein electrophoresis function: after the operation of stacking gel is completed, the power supply automatically connects to the separating gel program, avoiding repeated manual parameter resetting operations.
  • Automatic parameter generation function: after confirming a fixed constant value, the other two electrical indicators are automatically calculated and generated to prevent constant value setting errors caused by manual operation deviation.
  • Micro-current protection function: automatically switch to micro-current output after electrophoresis timing ends, which avoids sample diffusion after timing shutdown and prevents samples from over-running due to excessive electrophoresis time.
  • Complete safety performance monitoring: overvoltage, electric arc, no-load and load sudden change monitoring; overload/short-circuit monitoring, leakage protection, open circuit sound alarm; built-in power-off automatic recovery and independent pause/resume control keys.
  • The liquid crystal screen displays voltage, current, power and timing time simultaneously, and all core experimental parameters are clear at a glance.
  • Programmable storage for 10 experimental methods, and each experimental method contains a maximum of 2 running steps, facilitating one-key recall for conventional repeated experiments.
Serial No. Item Specification
1 Channel Structure Dual-channel independent control output
2 Single Channel Output Range Voltage:5–600V; Current:1–1200mA; Power:1–500W
3 Output Resolution Voltage 1V, Current 1mA, Power 1W
4 Display Mode 5.0-inch oversized LED capacitive touch screen
5 Timing Range 1min – 99h59min, fully adjustable
6 Overall Dimension 350×235×235mm (L×W×H)
7 Net Weight 5.5Kg
  • The internal dual-channel power circuit adopts independent isolation design. Parameter adjustment, start and stop of one channel will not interfere with the stable electrophoresis operation of the other channel, supporting synchronous operation of two different experimental schemes.
  • The dual-operation design of touch screen and digital keyboard ensures stable parameter setting through physical keyboard when the touch screen is affected by high humidity and reagent pollution in the laboratory, improving the service life and operation stability of the whole machine.
  • The automatic gel switching function for protein electrophoresis is customized for Western Blot gel preparation, which effectively reduces repeated manual parameter adjustment actions of experimenters and improves the result consistency of batch protein electrophoresis experiments.
  • The post-experiment micro-current holding function solves the problem of sample damage caused by delayed gel cutting and temporary work leave after electrophoresis, and no staff needs to wait beside the machine until the experiment is finished.
  • The multi-layer safety detection circuit will trigger an audible alarm and cut off the power output immediately under abnormal conditions such as short circuit, electric leakage and overvoltage, so as to effectively protect the electrophoresis tank, gel samples and internal power circuit from damage.
  • The device can store 10 groups of programmable experimental programs, matched with two-step segmented electrophoresis setting, to meet the gradient electrophoresis needs of nucleic acid and protein samples. The stored programs can be called with one key to shorten the preparation time before experiments.
  • If the laboratory needs to carry out two groups of electrophoresis experiments frequently at the same time, select this dual-channel independent control model. One device can replace two single-channel electrophoresis power supplies to reduce equipment procurement costs and save limited laboratory bench space.
  • For university teaching laboratories that carry out student comparative experiments: two independent channels can set different voltage and timing parameters to complete the comparative electrophoresis of control group and experimental group at one time, and improve the efficiency of classroom experimental teaching.
  • Laboratories focusing on long-term Western Blot protein electrophoresis experiments: the built-in automatic switching function of concentrated gel and separating gel avoids repeated manual parameter adjustment, reduces human errors in batch sample preparation and stabilizes experimental repeatability.
  • Comprehensive testing laboratories that frequently switch between high-voltage nucleic acid electrophoresis and conventional protein electrophoresis: the wide voltage output range of 5–600V covers high-speed nucleic acid separation and low-pressure protein electrophoresis, realizing multi-purpose of one machine without separate purchase of high-voltage and low-voltage power supplies.
  • Laboratory staff cannot be on duty for gel cutting after the experiment: the micro-current protection function can buffer the error of gel cutting time, avoid sample waste caused by delayed operation, which is suitable for laboratories with tight staff scheduling.
  • The laboratory municipal power supply is unstable and accidental power failure occurs occasionally: the power-off automatic recovery function can continue the electrophoresis program after power is restored, avoiding the overall failure of long-time gradient electrophoresis experiments.
  • Laboratories that need to store mature and fixed experimental formulas for a long time: the 10-group program storage function realizes one-key recall of mature experimental parameters, which is suitable for standardized laboratories with fixed experimental procedures.
  • Applicable matching equipment: high-voltage horizontal nucleic acid electrophoresis tank, vertical SDS-PAGE protein electrophoresis tank, mini vertical electrophoresis tank, which is perfectly matched with conventional molecular biology electrophoresis supporting equipment.
  • Contact the sales engineer to apply for free official electronic technical documents of the equipment.
  • Available downloadable documents: product operation manual, factory inspection certificate, complete technical parameter specification, overall dimension outline drawing, bidding technical parameter data sheet.
  • All materials are provided in PDF format, convenient for laboratory equipment file archiving, project bidding declaration and technical parameter verification work.
  1. Packaging form: Export-grade hard carton + integrated thick foam lining, all-round shock absorption and anti-collision protection to adapt to long-distance land and sea transportation.
  2. Standard lead time for in-stock products: 3–10 working days after order confirmation.
  3. Standard packing list: electrophoresis power main unit, power input cable, two groups of electrode connecting wires, product operation manual, factory inspection certificate.
  4. Support customized outer carton LOGO printing and neutral unbranded export packaging according to personalized demands of overseas customers.
1.Q: Can the two channels run electrophoresis experiments with different voltage, current and timing parameters independently at the same time?
A: The two channels adopt independent control circuit, each channel can be set separately, supporting asynchronous operation of two different experimental schemes.
2.Q: Will the equipment completely stop power output immediately after the electrophoresis timing countdown ends?
A: It will not cut off the power directly, and automatically switch to micro-current output to prevent sample diffusion and over-running after shutdown.
3.Q: What protective action will the device take when the electrophoresis tank has a short-circuit fault during operation?
A: The equipment will instantly trigger an open-circuit buzzer alarm and cut off all power output to prevent burnout of the internal power circuit.
4.Q: Can users freely edit, overwrite or delete the 10 pre-stored experimental methods?
A: Users can freely modify parameter content, overwrite old programs or delete unused experimental methods for flexible one-key recall.
5.Q: If the power is suddenly cut off during the experiment, can the equipment continue the experiment after power is restored?
A: Equipped with power-off automatic recovery function, it records the running state before power failure and automatically resumes electrophoresis after power supply is restored.
6.Q: Can each channel independently switch three working modes of constant voltage, constant current and constant power?
A: The whole machine supports free switching of three output modes, and both channels synchronously follow the main machine mode setting.
7.Q: Can users manually adjust the micro-current output intensity after the experiment?
A: The post-experiment micro-current adopts fixed logic output, no manual adjustment is required to stably protect the gel band morphology.
8.Q: What is the shortest adjustable time for short-time gel pre-electrophoresis balance treatment?
A: The minimum timing setting is 1 minute, which meets the parameter requirements of short-time experiments such as gel pre-equilibration.
9.Q: Can this dual-channel electrophoresis power supply run continuously for all-day batch sample testing?
A: The internal power module has stable heat dissipation performance, supporting long-term continuous boot operation for laboratory batch sample gel preparation.
10.Q: Can the matched electrode connecting wire be purchased separately for replacement after aging and damage?
A: The electrode connecting wire is a standard general accessory, which can be purchased separately for replacement after damage.
  • Send your procurement needs through official email, WhatsApp, independent station message board and online consulting window.
  • Clearly provide key information including purchase quantity, destination country, destination port, personalized function customization requirements and annual framework procurement intention.
  • Professional international sales team will issue a formal detailed quotation including unit price, delivery cycle and trade terms within 24 working hours.
  • Large-scale centralized procurement can enjoy stepped price discounts and priority production and delivery scheduling.
Applications 应用场景模块

Applications

Applications

Supporting diverse laboratory and industrial environments with practical instrument solutions.

Research Laboratories

Research Laboratories

Conduct SDS-PAGE protein separation, nucleic acid electrophoresis and molecular specimen analysis for life science research..

Universities and Education

Universities & Education

Complete protein & gene electrophoresis experiments for biotech, biology and chemistry course training.

Pharmaceutical and Chemical

Pharmaceutical & Chemical

Analyze target protein, separate biological ingredients and test biopharmaceutical sample purity.

Food Environmental and Industrial Testing

Food, Environmental & Industrial Testing

Identify microbial nucleic acid and detect protein composition in food and environmental samples..

Leave a message
Name *
Email *
Whatsapp/Phone
Message *
Verification Code *
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.