Laboratory Electrophoresis Power Supply

No.LF-EP300
Multi-functional laboratory electrophoresis power supply with constant voltage, constant current and constant power modes. It supports 4 gel units running simultaneously, built-in automatic protein electrophoresis program and full-range safety protection. Storable custom experimental protocols fit research, teaching, pharmaceutical and testing labs to boost experimental efficiency and data reproducibility.
$469.86
Model:
LF-EP300
  • Labcarta basic electrophoresis power supply front view
  • Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Laboratory Electrophoresis Power SupplyIlabcarta Technology Co., Ltd.
  • Description

  • Key Features

  • Parameter

  • Product Details

  • How to Choose

  • Packaging & delivery

  • Download

  • FAQ

  • Get a Quote


  • This basic electrophoresis power supply supports three output modes: constant voltage, constant current and constant power to meet diverse electrophoresis experimental demands.
  • Adopts transparent instrument housing, allowing direct observation of the internal structural layout of the equipment for routine inspection and maintenance.
  • Built-in dedicated protein electrophoresis program, which automatically switches to separating gel operation after concentrated gel electrophoresis is finished to reduce repeated manual parameter setting.
  • Equipped with automatic parameter generation function, micro-current protection after experiment, multi-dimensional safety monitoring, power-off recovery and pause-resume functions. It supports four groups of parallel output to drive multiple electrophoresis tanks simultaneously, and can store 10 sets of programmable experimental methods for repeated experiments.
  • Applicable to conventional nucleic acid electrophoresis, protein gel electrophoresis experiments for university teaching laboratories, scientific research institutions and testing laboratories.
  • Three optional output types: constant voltage, constant current, constant power, covering common electrophoresis experimental conditions.
  • Transparent outer casing design for intuitive viewing of internal components, convenient for equipment maintenance and fault checking.
  • Automatic gel switching for protein electrophoresis to avoid repeated manual parameter configuration.
  • Automatic parameter generation: set one fixed constant value, the other two electrical parameters will be generated automatically to prevent setting errors caused by manual operation.
  • Post-experiment micro-current function to avoid sample diffusion and over-running after timed shutdown.
  • Comprehensive safety protection: overvoltage, electric arc, no-load, load sudden change monitoring; overload, short-circuit monitoring, leakage protection, open-circuit alarm, power-off automatic recovery, pause/resume operation.
  • LCD screen synchronously displays voltage, current, power and running timing for real-time experimental status checking.
  • Four-channel parallel output, capable of driving multiple electrophoresis tanks to run experiments at the same time to improve experimental efficiency.
  • 10 groups of experimental programs can be stored, each program supports up to 2 segmented running steps
Serial Number Parameter Item Technical Specification
1 Output Range Voltage: 5–300V; Current: 1–400mA; Power: 1–75W
2 Output Resolution Voltage 1V, Current 1mA, Power 1W
3 Display Mode 192×64 LCD liquid crystal display screen
4 Timing Range 1min – 99h59min, continuously adjustable
5 Overall Dimension 308×242×100mm (L×W×H)
6 Net Weight 2Kg
  • Transparent casing design realizes visual internal observation, users can quickly judge the working state of internal circuit components during daily use.
  • Four groups of parallel output terminals support multi-tank simultaneous electrophoresis, suitable for laboratory batch sample testing.
  • The built-in concentrated gel and separating gel automatic switching program simplifies the operation flow of vertical protein electrophoresis and ensures consistent experimental parameters for batch samples.
  • Automatic electrical parameter matching function reduces the threshold for new operators to set experimental parameters and lowers the probability of experimental failure caused by parameter errors.
  • Micro-current holding after timing avoids sample damage caused by delayed gel cutting when operators cannot arrive on time after the experiment ends.
  • Multi-level safety circuit will trigger an alarm and cut off power output under short circuit, overvoltage and leakage faults to protect electrophoresis tanks, gel samples and the main power supply.
  • Storable segmented experimental programs are convenient for solidifying mature experimental schemes and one-click recall for repeated tests.
  • Laboratories with demand for batch electrophoresis experiments: four-way parallel output can drive multiple electrophoresis tanks at once to boost testing throughput.
  • Teaching laboratories for student electrophoresis experiments: transparent casing is convenient for teachers to explain the internal structure of power supply to students.
  • Laboratories focusing on conventional agarose nucleic acid electrophoresis and vertical SDS-PAGE protein electrophoresis: 5–300V output range fully matches low and medium voltage conventional electrophoresis requirements.
  • Experimental staff cannot be on-site for gel cutting after the experiment: micro-current anti-diffusion function effectively protects gel samples.
  • Laboratories with unstable mains power supply: power-off automatic recovery function can continue electrophoresis after power restoration to avoid long-time experimental failure.
  • Laboratories with fixed repeated experimental protocols: program storage function realizes quick parameter calling and standardized operation.

  • Packaging: Hard export carton with integrated thick foam liner for shockproof and crashproof protection for long-distance transportation.
  • In-stock lead time: 3–10 working days after order confirmation.
  • Standard packing list: electrophoresis power main unit, power cord, multi-group electrode connecting wires, operation manual, factory inspection certificate.
  • Neutral unbranded packaging and customized outer box printing are available upon customer requests.

Selling Units

Single item

Package size perbatch

380×320×160mm

Gross weight perbatch

6.7kg

 

Accessory Name Standard Quantity Description
Electrophoresis Power Supply Main Unit 1 set Main power supply for electrophoresis
Universal Power Cord 1 piece For equipment power supply
Red & Black Electrode Output Cables 4 sets Connect various electrophoresis cells
Paper Instruction Manual 1 copy Equipment operation guide
Factory Qualification Certificate 1 piece Factory inspection certificate
Warranty Card 1 piece 1-year warranty voucher
  1. Contact support team to get complete digital documents: bilingual specification sheet and electronic brochure PDF.
  2. Supporting files: operation manual, rotor daily maintenance guide.

1.Q: How many electrophoresis tanks can this device drive at the same time?

A: Four groups of parallel outputs support simultaneous connection of multiple electrophoresis tanks for synchronous operation.

2.Q: Will the power supply cut off output completely when the timing ends?

A: It will switch to micro-current output to prevent sample diffusion and over-running instead of direct power-off.

3.Q: What protection action will be triggered if the electrophoresis tank is short-circuited?

A: The device will trigger an audible alarm and cut off power output to protect the internal circuit of the host.

4.Q: Can users modify or delete the stored 10 experimental methods?

A: Users can edit, overwrite or delete stored experimental programs freely according to experimental needs.

5.Q: Can the equipment resume unfinished experiments after a sudden power failure?

A: Equipped with power-off automatic recovery function, it can continue electrophoresis after power is restored.

6.Q: Does the machine support constant voltage, constant current and constant power mode switching?

A: Three working modes are switchable to match different electrophoresis experimental requirements.

7.Q: Is the post-experiment micro-current value adjustable manually?

A: The post-experiment micro-current adopts fixed logic output without manual adjustment.

8.Q: What is the minimum adjustable timing value of the equipment?

A: The minimum setting time is 1 minute, meeting the demand of short-time pre-electrophoresis.

9.Q: Can the equipment run continuously for a long time for batch experiments?

A: The internal circuit has stable heat dissipation performance, supporting long-time continuous operation for batch laboratory experiments.

10.Q: Are electrode connecting wires replaceable separately?

A: Electrode wires are general standard accessories and can be purchased separately for replacement after aging and damage.

  1. end us model, quantity and destination country to get tiered pricing
  2. Free model recommendation & official PI within 24 hours
  3. Special discounts for universities and research labs
Leave a message
Name *
Email *
Whatsapp/Phone
Message *
Verification Code *
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.