• Wet fast blot transfer system for western blot protein gel transfer experiment
  • Wet Fast Blot Transfer SystemIlabcarta Technology Co., Ltd.
  • Wet Fast Blot Transfer SystemIlabcarta Technology Co., Ltd.
  • Wet Fast Blot Transfer SystemIlabcarta Technology Co., Ltd.
  • Wet Fast Blot Transfer SystemIlabcarta Technology Co., Ltd.
  • Wet Fast Blot Transfer SystemIlabcarta Technology Co., Ltd.
  • Wet fast blot transfer system for western blot protein gel transfer experiment
  • Wet Fast Blot Transfer SystemIlabcarta Technology Co., Ltd.
  • Wet Fast Blot Transfer SystemIlabcarta Technology Co., Ltd.
  • Wet Fast Blot Transfer SystemIlabcarta Technology Co., Ltd.
  • Wet Fast Blot Transfer SystemIlabcarta Technology Co., Ltd.
  • Wet Fast Blot Transfer SystemIlabcarta Technology Co., Ltd.

Wet Fast Blot Transfer System

No.coolBLOT
This dual-mode blot transfer device supports wet and semi-dry protein transfer, with built-in cooling, multi-gel independent operation, automatic drainage and circuit protection for stable Western blot experiments.
$4698.61
  • Wet fast blot transfer system for western blot protein gel transfer experiment
  • Wet Fast Blot Transfer SystemIlabcarta Technology Co., Ltd.
  • Wet Fast Blot Transfer SystemIlabcarta Technology Co., Ltd.
  • Wet Fast Blot Transfer SystemIlabcarta Technology Co., Ltd.
  • Wet Fast Blot Transfer SystemIlabcarta Technology Co., Ltd.
  • Wet Fast Blot Transfer SystemIlabcarta Technology Co., Ltd.
  • Product Overview

  • Key Features

  • Parameter

  • Product Details

  • How to Choose

  • Download

  • Packaging & delivery

  • FAQ

  • Get a Quote

  • Labcarta LF-coolBLOT Fast Wet Blotter combines the stability of traditional wet transfer and the high-speed advantage of semi-dry transfer.
  • This all-in-one machine is equipped with built-in power supply and constant temperature circulation cooling system, supporting wet transfer and semi-dry transfer two experimental modes.
  • It realizes simultaneous transfer of 1–4 gels, and the independent cavity design avoids electric field interference between gels.
  • It is equipped with real-time buffer temperature monitoring, automatic liquid drainage, automatic pipeline cleaning and multi-circuit safety protection.
  • The integrated power supply can also supply power for protein electrophoresis and nucleic acid electrophoresis experiments, suitable for conventional Western blot protein transfer in laboratories.
  • Dual transfer mode available: stable wet blotting and fast semi-dry blotting integrated.
  • Built-in power supply and thermostatic circulator continuously cool transfer buffer to prevent experiment failure caused by excessive temperature.
  • The host power supply can be independently used for protein electrophoresis and nucleic acid electrophoresis power supply.
  • Automatically switch from spacer gel running mode to separation gel mode without repeated parameter setting.
  • After experiment completion or shutdown, the buffer liquid is automatically drained, and the internal pipeline is cleaned automatically.
  • Parallel transfer for 1–4 gels, separate chambers prevent mutual electric field interference.
  • Four independent transfer clips with separate current detection for each gel.
  • Anti-reverse connection cover plus positive and negative clips with color distinction to prevent reverse assembly error.
  • Able to store 5 groups of running programs, each program supports up to 2 working steps.
  • Real-time buffer temperature display, automatic alarm when temperature exceeds limit.
  • Short-circuit protection and open-circuit protection for the main unit to ensure operational safety.
Serial No. Parameter Specification
1 Effective Transfer Area 82×92mm
2 Supported Gel Quantity 1–4 gels
3 Positive Electrode Material Platinum-plated titanium orifice plate
4 Negative Electrode Material Stainless steel orifice plate
5 Output Voltage Range 10–200V
6 Output Current Range 10–6000mA
7 Rated Power 200W
8 Output Mode Constant Voltage / Constant Current
9 Overall Dimension(L×W×H) 310×160×210mm
  • The equipment consists of integrated programmable power host, constant temperature cooling circulation module, multi-cavity transfer tank and color-coded transfer clips.
  • Before the experiment, fix the gel and transfer membrane inside the sponge liner of transfer clips, then install the clips into independent transfer chambers and pour transfer buffer solution.
  • Set operation parameters on the front control panel, the built-in circulator circulates and cools the buffer liquid during operation.
  • After the experiment finishes, the equipment automatically discharges residual buffer liquid and rinses the internal flow pipeline.
  • Each transfer clip adopts independent circuit design, which is convenient for checking the running state of single gel.
  • Special cover structural design effectively avoids wrong connection of positive and negative electrodes.
  • Select this fast wet blotter if you need both wet transfer and semi-dry transfer for Western blot testing.

  • Choose this device for batch protein transfer experiments requiring up to 4 gels per run to improve experimental efficiency.

  • Select the integrated all-in-one model if you need one device to complete electrophoresis power supply and protein transfer work at the same time.

  • Suitable for laboratories with strict requirements on experimental repeatability, temperature control effect and daily equipment maintenance convenience.

  • Contact Labcarta after-sales customer service to obtain full electronic technical documents free of charge.
  • Document contents: Product datasheet, equipment operation manual, dimensional drawing, parameter specification file.
  • Document usage: Laboratory bidding materials, experimental operation guidance, laboratory equipment file archiving.
  • Packaging: Standard export shockproof protective packaging.
  • Standard shipping time: 3–10 working days.
  • Complete packing list: Integrated power host, vertical transfer tank, transfer clip assembly, connecting wires, user manual, factory inspection certificate.
Q:Does this blotter support both wet transfer and semi-dry transfer experiments?
A:Yes, the machine supports two mainstream Western blot transfer modes.
2.Q:What is the maximum number of gels for one transfer run?
A:It supports synchronous transfer of 1 to 4 gels.
3.Q:Is there temperature control to prevent overheating during transfer?
A:Built-in constant temperature circulator continuously cools buffer liquid, matched with overtemperature automatic alarm function.
4.Q:Can the integrated power supply drive electrophoresis equipment directly?
A:The integrated power module can supply power for protein electrophoresis and nucleic acid electrophoresis equipment.
5.Q:Is manual drainage required after the experiment?
A:No, buffer liquid is drained automatically, and internal pipelines are cleaned automatically synchronously.
6.Q:Voltage, current and power parameters of the power supply?
A:Voltage 10–200V, current 10–6000mA, rated power 200W.
7.Q:Is it easy to fail the experiment due to reversed positive and negative assembly?
A:Color differentiated electrodes plus anti-reverse cover design effectively avoid reverse installation errors.
8.Q:How many groups of running programs can be stored inside the machine?
A:5 groups of programs can be stored, each program supports up to 2 operation steps.
9.Q:Materials of positive and negative electrodes?
A:Positive electrode: platinum-plated titanium orifice plate; Negative electrode: stainless steel orifice plate.
  • You can send purchase inquiries via website message, official email and WhatsApp.
  • Please clearly mark product purchase quantity and detailed receiving address when sending inquiry.
  • We will calculate accurate logistics cost according to your delivery address.
  • After confirming all order information, we will issue an official formal PI quotation within 24 working hours.
  • Large-volume bulk procurement can enjoy exclusive volume discount.
Applications 应用场景模块

Applications

Applications

Supporting diverse laboratory and industrial environments with practical instrument solutions.

Research Laboratories

Research Laboratories

Conduct SDS-PAGE protein separation, nucleic acid electrophoresis and molecular specimen analysis for life science research..

Universities and Education

Universities & Education

Complete protein & gene electrophoresis experiments for biotech, biology and chemistry course training.

Pharmaceutical and Chemical

Pharmaceutical & Chemical

Analyze target protein, separate biological ingredients and test biopharmaceutical sample purity.

Food Environmental and Industrial Testing

Food, Environmental & Industrial Testing

Identify microbial nucleic acid and detect protein composition in food and environmental samples..

Leave a message
Name *
Email *
Whatsapp/Phone
Message *
Verification Code *
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.