• Labcarta Decolorizing Shaker Intelligent Transference
  • Intelligent Transference Decolorizing ShakerIlabcarta Technology Co., Ltd.
  • Intelligent Transference Decolorizing ShakerIlabcarta Technology Co., Ltd.
  • Intelligent Transference Decolorizing ShakerIlabcarta Technology Co., Ltd.
  • Intelligent Transference Decolorizing ShakerIlabcarta Technology Co., Ltd.
  • Intelligent Transference Decolorizing ShakerIlabcarta Technology Co., Ltd.
  • Labcarta Decolorizing Shaker Intelligent Transference
  • Intelligent Transference Decolorizing ShakerIlabcarta Technology Co., Ltd.
  • Intelligent Transference Decolorizing ShakerIlabcarta Technology Co., Ltd.
  • Intelligent Transference Decolorizing ShakerIlabcarta Technology Co., Ltd.
  • Intelligent Transference Decolorizing ShakerIlabcarta Technology Co., Ltd.
  • Intelligent Transference Decolorizing ShakerIlabcarta Technology Co., Ltd.

Intelligent Transference Decolorizing Shaker

No.LSK18-R07-S
Designed for time-dependent and low rpmsensitiveshaking applications such as ELISAwashes, enzymeimmunoassays, proteinsynthesis, hybridizationstaining/destaininggels,immune precipitation andWestern blots, cell culture, pharmaceutical profilingetc.
$160.50
Model:
LSK18-R07-S
  • Labcarta Decolorizing Shaker Intelligent Transference
  • Intelligent Transference Decolorizing ShakerIlabcarta Technology Co., Ltd.
  • Intelligent Transference Decolorizing ShakerIlabcarta Technology Co., Ltd.
  • Intelligent Transference Decolorizing ShakerIlabcarta Technology Co., Ltd.
  • Intelligent Transference Decolorizing ShakerIlabcarta Technology Co., Ltd.
  • Intelligent Transference Decolorizing ShakerIlabcarta Technology Co., Ltd.
  • Description

  • Key Features

  • Parameter

  • Product Details

  • How to Choose

  • Packaging & delivery

  • Download

  • FAQ

  • Get a Quote

  • LSK18-R07-S intelligent transference decolorizing shaker is developed for low-rpm and time-sensitive shaking experiments, including ELISA plate washing, enzyme immunoassay, protein synthesis, gel staining and destaining for nucleic acid hybridization, immune precipitation, Western blot, cell culture and pharmaceutical screening.
  • It adopts fixed 7° rocking tilt angle with compact body to save bench space. Equipped with DC driving motor, the adjustable speed range is 10–80rpm. Dual independent LED screens display rotation speed and runtime separately, supporting continuous operation and timed auto-stop operation with timer ranging from 1min to 99h59min.
  • The unit is fitted with integrated fixed work plate, total power 50W, auto-adaptive 100~240V 50/60Hz voltage, IP21 protection class. Overall dimension 294×348×123mm, net weight 3.1kg, max load capacity with platform 2kg, designed for long-term low-speed mild incubation and mixing.
  • Fixed 7° mild rocking motion angle: Low-speed gentle shaking prevents damage or detachment of protein, cell and gel samples, ideal for fragile blots and gel specimens
  • 2kg rated load & 10–80rpm wide low-speed range: Covers all low-speed mixing workflows of immunoincubation and gel destaining
  • Dual independent LED separate display: Speed and timer data are shown without visual interference for clear parameter reading
  • Dual operation modes: Continuous running and timing auto-stop, supporting unattended overnight experiments
  • 1min–99h59min long-range electronic timer: Enables multi-day incubation and destaining without repeated manual reset
  • Integrated fixed work plate: Stable platform structure avoids sliding of ELISA plates, petri dishes and incubation boxes
  • Compact minimalist body: Small footprint to save limited bench space in molecular biology labs
Specifications LSK18-R07-S
Tilt angle 7°
Max. load capacity(with platform) 2kg
Motor type DC motor
Motor input power 20W
Motor output power 16W
Speed range 10-80rpm
Speed display LED
Timer display LED
Time settings range 1min-99h59min
Voltage, Frequency 100-240V, 50/60HZ
Power 50W
Weight 3.1kg
Permissible ambient temperature and humidity 5-40°C, 80%RH
Dimension[W×D×H] 294×348×123mm
Protection class IP21
  • Labware placement and fixation
    Place ELISA plates, gel incubation boxes and petri dishes flat on integrated fixed work plate; the flat stable surface prevents sliding during low-speed reciprocating rocking.
  • Power connection & self-check standby
    Connect 100~240V universal AC power supply, dual LED screens light up automatically for unit self-check and parameter adjustment standby.
  • Operation mode & parameter programming
    Select continuous running or timed auto-stop mode as required; adjust knob to set 10–80rpm rocking speed and 1min–99h59min running duration, speed and timer are displayed on separate LED panels.
  • Low-speed mild reciprocating rocking operation
    Start the shaker after parameter confirmation, it performs gentle back-and-forth rocking at fixed 7° tilt angle, low impact protects fragile gel and Western blot samples for long-time incubation and destaining.
  • Standard post-test shutdown sequence
    Timed mode auto stops when time expires; continuous mode requires manual shutdown. Cut off power, take out all labware and wipe residual buffer liquid off the work plate.
  • Long-term shutdown storage maintenance
    Disconnect power during long idle periods, remove all labware and wipe the unit surface clean; store under dry 5–40℃ low-humidity environment to extend service life of motor and electronic components.
Application distinction between 7° low-tilt shaker and high-tilt 3D shaker
Motion Characteristic: This unit delivers ultra-mild reciprocating rocking at tiny 7° tilt angle with minimal impact; 10° 3D shaker features larger swing amplitude and stronger mixing force.
Applicable samples: This model is optimized for fragile blots, nucleic acid gels and ELISA plates; high-tilt versions fit cell suspensions and crude extracts mixing.
Load capacity matching rule
Total weight of platform, labware and samples shall not exceed 2kg; overload leads to unbalanced rocking, accelerates motor wear and shortens service life.
Scenario matching for operation modes
Prioritize this unit with timed auto-stop function for overnight gel destaining and long-duration blot blocking incubation; continuous mode fits short-time rapid mixing.
Lab space matching judgment
Compact bench footprint, ideal for labs with limited counter space or multiple instruments to be placed simultaneously.

Application Scenarios

1. Research Laboratories: Western blot blocking & antibody incubation, long-time mild destaining of nucleic acid gel, low-speed mixing for immune precipitation, oscillation of micro protein synthesis samples.
2. Universities & Education: Undergraduate molecular biology gel experiments, postgraduate full-process Western blot training, ELISA wash teaching trials.
3. Pharmaceutical & Chemical: Cell incubation for drug target screening, low-speed oscillation screening of micro peptide proteins, pre-treatment mixing of biochemical immune samples.
4. Food, Environmental & Industrial Testing: Incubation for food protein blot detection, low-speed oscillation of environmental microbial immunoassay samples.
5. Medical & Healthcare: Washing of clinical ELISA specimens, staining and destaining of pathological gel specimens, mild mixing of biological preparations.
  • Packaging structure: Standard export hard color carton fully lined with high-density shock-absorbing foam, separate slots for main unit and power cord to prevent collision damage during long sea and land transit.
  • Bulk order protection: Reinforced thickened protective structure is applied by default for large-volume export orders to reduce transportation damage risk.
  • Standard package accessories: LSK18-R07-S shaker main unit, matching wide-voltage power cord, full printed operation manual; sample racks and dedicated clamps are optional accessories not included.
  • Package size note: Outer carton dimension and full-set gross weight are estimated reference values only, final data subject to actual factory outgoing packaging.
  • In-stock lead time: Standard models without custom accessories ship within 3–10 working days.
  • Optional logistics channels: Sea freight, air freight and full-truck land transport available, dedicated logistics line for bulk overseas export of laboratory instruments.

Selling Units

Single item

Package size perbatch

41.5*38*25cm

Gross weight perbatch

4.4kg

 


Name Qty
Power Cable 1 pc
User Manual 1 copy
Packing List / Certificate of Conformity 1 set
Warranty Card 1 copy
Contact customer service to receive full electronic documents free of charge: Complete LSK18-R07-S technical datasheet, standard operation guide for Western blot destaining, dimension outline drawings, factory motor stability & max load inspection report, available for tender filing of research institutes and university molecular biology departments.

  • What is the fixed rocking tilt angle of this decolorizing shaker, can the tilt angle be adjusted manually?
    Fixed at 7° reciprocating rocking angle, no angle adjustment structure built in.
  • What is the maximum total load of work plate, labware and samples?
    Rated max total load 2kg, overload operation is forbidden.
  • What is the adjustable rotation speed range, minimum and maximum speed?
    Continuously adjustable speed range 10rpm–80rpm.
  • What two operation modes does the unit support?
    Uninterrupted continuous running mode, timed auto-stop mode.
  • What is the maximum available electronic timer duration for long experiments?
    Max setting 99 hours 59 minutes, minimum 1 minute, supports multi-day overnight trials.
  • Do rotation speed and runtime share one single display screen?
    No, two independent LED screens show parameters separately without mutual interference.
  • Protection class and permissible stable operating temperature & humidity?
    Protection class IP21; stable operation environment 5–40℃, relative humidity ≤80%RH without condensation.
  • Overall dimension (W×D×H) and net weight of main unit?
    Dimension 294×348×123mm, net weight 3.1kg.
  • What advantage does the body structure bring to limited lab bench space?
    Minimalist compact body takes less countertop area to save lab operating space.
  • What fragile biological samples is this unit specially designed for?
    Optimized for Western blot membranes, nucleic acid gels and ELISA plates; low-tilt gentle rocking prevents sample damage.
  • Total unit power, motor input and output power respectively?
    Total unit power 50W; motor input power 20W, motor output power 16W.
  • Can the unit work directly in overseas 110V labs worldwide?
    Auto-adaptive 100–240V wide voltage with automatic 50/60Hz frequency detection, no extra transformer required.
  • Is the work plate detachable movable or integrated fixed structure?
    Integrated fixed work plate with stable structure, no displacement during rocking.
  • What routine molecular biology experiments is this equipment suitable for?
    Western blot blocking & destaining, nucleic acid gel staining & destaining, ELISA plate washing, immune precipitation, low-speed incubation mixing for cell culture.

Specify required model, total order quantity and destination country to receive tiered bulk discount quotation
Free customized lab mixing scheme for university molecular biology labs and pharmaceutical biochemistry R&D departments, official PI quotation issued within 24 working hours
Exclusive tiered volume discounted pricing available for mass procurement from university key research labs and pharmaceutical enterprises
Applications 应用场景模块

Applications

Applications

Supporting diverse laboratory and industrial environments with practical instrument solutions.

Research Laboratories

Research Laboratories

Microbial incubation, sample extraction and oscillatory reaction for biochemical research.

Universities and Education

Universities & Education

Biology and chemistry shaking culture & extraction teaching experiments.

Pharmaceutical and Chemical

Pharmaceutical & Chemical

Bacteria cultivation, medicinal extraction and chemical oscillation reaction

Food Environmental and Industrial Testing

Food, Environmental & Industrial Testing

Microbial culture and sample extraction pretreatment of food and water samples.

Leave a message
Name *
Email *
Whatsapp/Phone
Message *
Verification Code *
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.