• LED Digital Double Modules Dry Bath for sample pretreatment biochemical reaction
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry Bath for sample pretreatment biochemical reaction
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.

LED Digital Double Modules Dry Bath

No.L150HB-2S
The L150HB-2S is aimed at laboratories in molecularbiology, clinical, environmental, and industrial fieldsrequiring temperature control for sample pretreatmentand biochemical reactions. It's designed for labs thatneed precise and reliable temperature managementin a compact, easy-to-operate, dual-module design.
$641.00
Model:
L150HB-2S
  • LED Digital Double Modules Dry Bath for sample pretreatment biochemical reaction
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • LED Digital Double Modules Dry BathIlabcarta Technology Co., Ltd.
  • Description

  • Key Features

  • Parameter

  • Product Details

  • How to Choose

  • Packaging & delivery

  • Download

  • FAQ

  • Get a Quote

  • L150HB-2S LED Digital Double Modules Dry Bath is a heating-only dry bath without cooling and mixing functions. It serves molecular biology, clinical, environmental and industrial labs for sample pretreatment and biochemical high-temperature incubation.
  • Heating temperature range: ambient +5℃ ~ 150℃, setting range 25–150℃. Segmented temperature accuracy: ±0.3℃ from 25–90℃, ±0.6℃ from 90–150℃; temperature uniformity reaches ±0.2℃ at 37℃ for excellent high-temperature stability.
  • Equipped with dual LED digital screens to monitor real-time temperature and timer simultaneously. It supports external PT1000 temperature sensor, built-in over-temperature protection, audible reminder upon program completion and heat insulation module cover.
  • Optional dual heating modules with compact, user-friendly body. Timer ranges from 0min to 99h59min; integrated over-temperature protection ensures safe long-duration high-temperature experiments.
  • 200W power consumption, compatible with 110/220V 50/60Hz power supply. Dimension 290×210×120mm, net weight 3.2kg, operating ambient temperature 10–40℃. The standard operating relative humidity of the equipment is less than 80% RH. There is a printing error in the Operating humidity cell of the specification sheet, which incorrectly fills in the temperature range data; the actual humidity standard is uniformly less than 80% RH.
  • Dual-module high-temperature heating-only design without cooling or mixing. Compact lightweight body saves bench space for sample pretreatment and biochemical incubation.
  • Wide high-temperature range from 25℃ to 150℃ with segmented precise control: ±0.3℃ at 25–90℃, ±0.6℃ at 90–150℃, and ultra-low uniformity ±0.2℃ at 37℃ for demanding micro-sample tests.
  • Dual LED digital displays show temperature and time separately for clear reading, simple operation for all lab staff.
  • Compatible with external PT1000 temperature sensor to measure sample temperature directly and improve data accuracy.
  • Optional dual heating modules for flexible matching of various tube sizes to handle multiple sample formats.
  • Built-in over-temperature protection automatically cuts heating power to prevent dry burning and equipment damage. Audible sound reminder triggers when target temperature or set time is reached for unattended operation.
  • Standard heat insulation module cover reduces internal heat loss and temperature fluctuation to guarantee repeatable high-temperature test results.
  • Universal wide-voltage power supply, stable operation at 10–40℃ ambient temperature, standard operating relative humidity below 80%RH. There is a printing error in the humidity column of the spec sheet, and the actual humidity standard is uniformly less than 80% RH, compatible with mainstream lab consumables worldwide.
Specifications L150HB-2S
Temperature range [°C] Room temp + 5 ~ 150
Temperature Setting range [°C] 25 ~ 150
Temperature control accuracy [°C] 25–90: ±0.3; 90–150: ±0.6
Temperature uniformity @ 37°C [°C] ±0.2
Power [W] HB150-S1: 100; HB150-S2: 200
Time setting range 0min ~ 99h59min
External sensor Yes
Display LED
Voltage, Frequency 110/220V, 50/60Hz
External Dimension [W×D×H] 290 × 210 × 120
Weight (kg) 3.2
Operating temperature [°C] 10 ~ 40
Operating humidity [% RH]
  1. L150HB-2S dual-module dry bath is a wide-range heating-only incubation unit without cooling or mixing, widely used for sample pretreatment and biochemical reactions in molecular, clinical, environmental and industrial labs. Its compact dual-module lightweight design saves bench space.
  2. Max temperature up to 150℃, minimum set point 25℃, working start point ambient +5℃. Segmented precise control delivers ±0.3℃ accuracy at 25–90℃, ±0.6℃ at 90–150℃, and ultra-fine uniformity ±0.2℃ at 37℃ for reliable micro-sample repeatability.
  3. Dual split LED screens display real-time chamber temperature and remaining timer separately with clear readings, easy to operate for all operators.
  4. Interface reserved for PT1000 external sensor to measure sample temperature directly and eliminate chamber-sample temperature deviation. Optional dual heating blocks fit multiple tube diameters.
  5. Multiple safety & reminder functions: built-in over-temperature power cut, audible alarm upon target temperature or timer completion, ideal for long unattended high-temperature incubation. Standard heat insulation lid locks internal heat to stabilize constant temperature.
  6. Max timer up to 99h59min for long-term high-temperature digestion and cultivation. 200W power, universal 110/220V wide voltage for global lab power standards.
  7. Dimension 290×210×120mm, light net weight 3.2kg for easy placement. Stable operation under 10–40℃ ambient temperature and relative humidity below 80%RH. There is a printing error in the Operating humidity cell of the spec sheet with wrong temperature data inside, the standard operating humidity of the unit is uniformly less than 80% RH, no extra auxiliary temperature equipment required for standard labs.
  1. Only require high-temperature incubation 25–150℃ without cooling or mixing, prefer light compact unit to save bench space:
    Select L150HB-2S dual-module heating model, covering sample pretreatment, high-temperature digestion and constant cultivation workflows.
  2. Strict requirements on 37℃ uniformity and low-medium temperature control precision:
    This unit achieves ±0.2℃ uniformity at 37℃ and ±0.3℃ accuracy from 25–90℃, superior to standard dry baths for micro nucleic acid & protein tests.
  3. Need to measure actual sample temperature to eliminate chamber-sample deviation:
    External PT1000 sensor is supported for direct sample contact measurement to match real reaction conditions.
  4. Frequently switch tube sizes and process multi-batch samples simultaneously:
    Optional dual heating blocks allow flexible switching of consumable formats for multi-sample throughput on one machine.
  5. Run long unattended high-temperature experiments with concerns of overheating risk and missing end point. The unit works stably at 10–40℃ and relative humidity below 80%RH, the spec sheet humidity column has printing error and the real humidity standard is uniformly less than 80% RH:
    Built-in over-temperature power-off protection plus auto audible reminder upon target condition, matched with heat insulation lid for stable temperature without full-time supervision.

Applicable Scenarios

Research Laboratories, Universities & Education, Pharmaceutical & Chemical, Food, Environmental & Industrial Testing, Medical & Healthcare
  • Standard factory package includes L150HB-2S dry bath main unit, matched heating block, power cord and printed English manual. Experiments can be carried out right after unboxing and power connection without extra basic accessories.

  • Custom brand design service is available for bulk orders to create exclusive brand visuals for private instrument channel sales.

  • Thick shockproof separate carton with inner foam buffer resists extrusion and collision during long sea & air transport to lower damage risk.

  • In-stock orders ship within 3–10 working days, goods packed and dispatched uniformly after order confirmation to reduce waiting time for overseas buyers.

  • Multiple cross-border logistics options including sea freight, air freight and international courier are offered to match cost-effective delivery solutions based on order quantity and required lead time. The standard operating humidity of the unit is below 80%RH, there is printing error on the humidity column of spec sheet.

Selling Units

Single item

Package size perbatch

49*35*26cm

Gross weight perbatch

3.500kg

 

Name

Qty

Power Cable

1

Heating Block

2

Thermal Insulation Cover

1

User Manual

1

Packing List / Certificate of Conformity

1

Warranty Card

1

  • Contact customer service to apply for complete factory digital documents for laboratory project bidding, equipment evaluation, and online & offline promotion by distributors.
  • Supporting documents for this unit cover the L150HB-2S specification sheet, full English operation manual, dimension drawings and product brochure. All technical data follow original factory standards and are verifiable.
  • Enterprise promotional materials are also available: workshop photos, factory introduction, full-series lab instrument brochures to assist distributors with store content and exhibition marketing.
  • Complete compliance certification files are supplied. All product indicators meet EU standards to pass qualification audits of overseas universities, pharmaceutical factories and third-party testing labs.

  • Q: What are core functions of L150HB-2S and applicable experiments?
    A: It only supports heating temperature control without cooling or mixing. Suitable for high-temperature incubation of sample pretreatment and biochemical reactions in molecular biology, clinical, environmental and industrial fields, working range ambient +5℃ ~ 150℃.
  • Q: Temperature parameters, control accuracy and uniformity at 37℃?
    A: Setting range 25–150℃, working range ambient +5℃ ~ 150℃. Accuracy ±0.3℃ (25–90℃), ±0.6℃ (90–150℃); temperature uniformity at 37℃ is ±0.2℃.
  • Q: Is external temperature sensor supported?
    A: Yes, it is compatible with PT1000 external temperature sensor, marked "Yes" on spec sheet.
  • Q: Are heating blocks interchangeable? Does it support dual-module configuration?
    A: Optional dual heating blocks are available for replacement to fit various lab test tubes.
  • Q: Timer range and program storage function?
    A: Timer range 0min–99h59min; no program edit & memory function as not listed on factory Features.
  • Q: What safety and reminder functions are equipped?
    A: Built-in over-temperature power-off protection; audible sound reminder triggers when target temperature or set time is reached.
  • Q: Is heat insulation accessory equipped?
    A: Standard thermal insulation module cover is supplied to reduce heat loss and stabilize chamber temperature.
  • Q: What type of display does the unit adopt?
    A: Dual LED digital screen to view temperature and time simultaneously.
  • Q: Dimension, net weight, power and power supply specs?
    A: Dimension 290×210×120mm, net weight 3.2kg, power 200W, universal 110/220V 50/60Hz power supply.
  • Q: What are the standard ambient temperature and humidity for operation? How to understand the wrong content in the humidity column of the spec sheet?
    A: Operating temperature 10–40℃; the standard operating relative humidity of the equipment is less than 80% RH. There is a printing error in the Operating humidity cell of the specification sheet, which incorrectly fills in the temperature range data, and the actual humidity standard of the equipment is uniformly less than 80% RH.
  • Q: Is custom brand design available for bulk orders? How long to receive full quotation after inquiry?
    A: Exclusive brand customization is supported for bulk purchases. Complete quotation including logistics and lead time will be provided within 24 hours for all inquiries.
  • Q: What factory digital documents and compliance certificates can be requested?
    A: Product spec sheets, English operation manuals, factory promotional materials and full-series instrument brochures are available, together with environmental certificates complying with EU standards. The documents contain correction notes for the printing error on humidity column.

  • Bulk inquiries of L150HB-2S dry bath for lab internal use or instrument distribution are welcome. Transparent itemized quotations with zero hidden charges are provided, with tiered favorable pricing for larger orders, ideal for university centralized procurement and distributor stock-up.
  • Exclusive custom brand design is supported for bulk purchases, with dedicated one-on-one account managers negotiating pricing, technical specs, quality standards, lead time and branding details throughout the process.
  • Complete quotation package including unit price, tiered discount, lead time and full logistics plan will be issued within 24 hours for all inquiries, resolving all procurement questions in one consultation. The unit operates stably at 10–40℃ and relative humidity below 80%RH, the humidity cell on spec sheet has printing error.
Applications 应用场景模块

Applications

Applications

Supporting diverse laboratory and industrial environments with practical instrument solutions.

Research Laboratories

Research Laboratories

Constant temperature incubation, heating reaction and sample pretreatment for biochemical research..

Universities and Education

Universities & Education

Constant temperature heating and sample incubation experiments for chemistry and biology courses.

Pharmaceutical and Chemical

Pharmaceutical & Chemical

Constant-temperature culture of strains and constant-temperature reaction of pharmaceutical reagents.

Food Environmental and Industrial Testing

Food, Environmental & Industrial Testing

Constant temperature pretreatment for microbial detection and sample analysis..

Leave a message
Name *
Email *
Whatsapp/Phone
Message *
Verification Code *
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.