• Thermal Cycler Gradient laboratory temperature gradient PCR gene amplification equipment
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler Gradient laboratory temperature gradient PCR gene amplification equipment
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.

Thermal Cycler Gradient

No.L1000TC-G-Pro
L1000TC-G-Pro is applicable to molecular labs engaged in gene detection, cloning, expression and mutagenesis, serving pharmaceutical, agricultural, food industries as well as life science, chemical and bacteriological research labs. Suitable for constant-temperature work like sample incubation, reagent heating, enzymatic reaction, growth observation, fermentation analysis and tissue culture, it safely heats flammable chemicals and fits daily bacteriological incubation operations.

The Labcarta Gradient Thermal Cycler delivers precise thermal control for gene amplification and molecular biology workflows. This instrument integrates seamlessly with advanced incubator equipment for reliable performance.

$3944.40
Model:
L1000TC-G-Pro
  • Thermal Cycler Gradient laboratory temperature gradient PCR gene amplification equipment
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Thermal Cycler GradientIlabcarta Technology Co., Ltd.
  • Description

  • Key Features

  • Parameter

  • Product Details

  • How to Choose

  • Packaging & delivery

  • Download

  • FAQ

  • Get a Quote

L1000TC-G-Pro Professional Gradient Thermal Cycler is a high-precision temperature-controlled amplification instrument for research institutes, pharmaceutical R&D departments and high-end third-party molecular testing labs. It is suitable for complex molecular experiments including gene cloning, primer annealing temperature gradient screening, gene expression quantification, site-directed mutagenesis, long-fragment amplification and Touchdown PCR, widely applied in new drug development, agricultural molecular breeding, precise food microbial identification, life science basic research, bacterial pathogen screening, cell & tissue constant-temperature incubation and other workflows.

Compatible consumables include 96×0.2mL single PCR tubes, 12 strips of 8×0.2mL tubes, skirtless / semi-skirted / fully skirted 0.2mL 96-well microplates. Full block temperature range 0–105℃, independent heated lid range 30–115℃, temperature display accuracy ±0.1℃, well-to-well uniformity ±0.2℃ at 55℃, max heating/cooling rate 5℃/sec. Equipped with professional gradient temperature control system: gradient setting range 30–105℃, gradient span adjustable 1–42℃ (input 0 to disable gradient). Aerospace-grade aluminum heating block adopts long-life Peltier heating & cooling elements plus edge temperature compensation technology to minimize zone temperature difference and deliver highly repeatable results. 7-inch 1024×600 high-resolution color touch screen supports dual control modes: Block bulk temperature regulation & precise single-Tube control. Built-in computer host system with dual communication ports (USB + WIFI); single USB flash drive stores over 20000 experimental protocols. It features auto power-off recovery protection, multi-level user account & password permission management, one-click fast incubation for enzyme digestion, ligation and ELISA constant-temperature assays. Multiple units can be remotely controlled by one single PC via LAN; USB supports data import/export and firmware upgrade. Compact dimension 280×370×250mm, lightweight net weight only 9.5kg, universal dual voltage 100~120V/200~240V for global labs. It serves as top-tier PCR equipment for professional labs requiring gradient condition screening, remote network management and mass program storage.

  • Professional core gradient temperature control system: Full-range gradient setup 30–105℃, adjustable gradient span 1–42℃. Up to 8 annealing temperature parallel tests run simultaneously in one batch to rapidly screen optimal primer conditions and shorten method development cycles.
  • Ultra-high temperature uniformity & precision: Wide block range 0–105℃, well-to-well uniformity ±0.2℃ at 55℃, display accuracy ±0.1℃. Long-life Peltier semiconductors combined with edge temperature compensation ensure consistent parallel amplification results across all wells.
  • Full compatibility with all 96-well consumables: Fits single tubes, 8-strip tubes, skirtless/semi/fully skirted microplates without block replacement, covering both high-throughput screening and trace precious sample workflows.
  • Dual WIFI+USB communication & integrated host system: Multiple thermal cyclers remotely controlled by one PC via LAN; USB flash drive stores over 20000 protocols, exports experimental data and upgrades firmware, enabling traceable data archiving for papers and compliance testing.
  • 7-inch high-resolution touch screen: 1024×600 graphical UI, visual program editing, real-time display of run progress & remaining time for easy complex gradient programming by untrained staff.
  • Multi-level user permission management: Multiple user accounts with independent passwords separate administrator and operator access, standardizing lab data management and meeting GLP compliance standards.
  • Multi-purpose one-click incubation mode: Beyond standard PCR amplification, one-tap constant-temperature incubation supports enzyme digestion, ligation, ELISA, sample incubation and reagent preheating for various biochemical assays.
  • Switchable dual temperature control modes: Block bulk control for high-throughput batch screening; precise single-Tube control for fine amplification of trace low-copy precious samples.
  • Multi-layer safety protection: Auto program cache during power failure to resume full cycles after power recovery; multi-level adjustable heated lid temperature & operation modes eliminate sample loss from evaporation & condensation.
  • Lightweight wide-voltage desktop design: Net weight only 9.5kg (lighter than basic model); auto-adaptive global 100~240V power supply, no extra transformer required for overseas research labs.
Category Parameter Item L1000TC-G-Pro Specification
Sample Loading Compatibility Consumables 96×0.2mL single PCR tubes, 12×0.2mL 8-strip tubes, 0.2mL 96-well microplates (skirtless / semi-skirted / fully skirted)
Temperature Control System Adapter Block Material Aluminum alloy
Heating Temp Range 0–105℃
Lid Temp Range 30–115℃
Temp Display Accuracy ±0.1℃
Well Uniformity @55℃ ±0.2℃
Max Heating/Cooling Rate 5℃/sec
Gradient Setting Range 30–105℃
Adjustable Gradient Difference 1–42℃, input 0 to disable gradient function
Control Core Peltier integrated heating/cooling independent zone PID control with edge compensation
Human-Machine Interface Display 7-inch color touch LCD 1024×600 resolution (1024×600)
Input Mode Capacitive touch panel with graphical menu
Software System Host Control System Built-in upper computer linkage system for multi-instrument synchronous management
File Storage Capacity Over 20000 user-defined programs stored via U-disk
Account Management Multi-user accounts & password hierarchical authority control
Communication Interfaces Data Ports Dual USB & WIFI, LAN computer linkage
Firmware Upgrade Local U-disk upgrade, remote multi-unit control via WIFI LAN
Safety Functions Power-off Protection Auto resume incomplete cycles after power recovery
Lid Protection Multi-adjustable lid temp & modes to prevent sample evaporation & condensation
Electrical Spec Voltage & Frequency Auto-adaptive wide voltage 100~120V / 200~240V 50/60Hz
Dimension & Weight Overall Size(W×D×H) 280×370×250mm
Net Unit Weight 9.5kg
Operating Ambient Ambient Temp 5–40℃
Ambient Humidity ≤80%RH non-condensing
  • Sample dispensing & loading: Dispense nucleic acid template, primers and enzyme reaction mix into matched PCR consumables, seal to avoid evaporation, place evenly into aluminum heating block; select single tubes, 8-strips or 96-well plates as required.
  • Power-on system login: Boot after connecting wide-range power supply, 7" high-definition touch screen completes self-check; log in with personal account & password with separated administrator/operator permissions.
  • New gradient program creation / recall: Recall from over 20000 stored protocols via USB flash drive, or create new gradient workflows; set gradient range 30–105℃ and adjustable span 1–42℃, edit denaturation, annealing and extension cycles, compatible with Touchdown & Long PCR special assays.
  • Operation mode selection: Select Block bulk control for high-throughput batch screening; switch to precise single-Tube control for trace precious low-copy samples; set adjustable heated lid temperature 30–115℃ to eliminate condensation & sample loss.
  • Start amplification & remote monitoring: Tap Run to launch parallel gradient amplification; connect PC via WIFI LAN to monitor multiple thermal cyclers simultaneously from one computer, real-time remaining time displayed on screen.
  • Power failure emergency recovery: If power cuts off mid-experiment, the unit loads cached protocols automatically after power restoration and continues unfinished cycles without sample re-preparation or program re-editing.
  • Data export / firmware upgrade (optional): Export raw gradient data via USB flash drive for archiving post-test; support local firmware upgrade through USB for functional iteration optimization.
  • Post-test sampling & cleaning: After all cycles finish, wait for block cooling to safe temperature then retrieve consumables; power off main unit, wipe residual reagents on heating block and log out personal account.

Core Difference Between Two Models

L1000TC-S (Basic model): No gradient, no WIFI/USB communication, no built-in host, no user permission, only 200 program storage, net weight 11kg; only for mature fixed amplification protocols & basic teaching experiments.
L1000TC-G-Pro (Pro Gradient model): Adjustable 1–42℃ gradient, dual WIFI+USB communication, integrated main control PC, hierarchical user accounts, massive 20000+ USB storage, lightweight 9.5kg; ideal for primer gradient screening, R&D labs, third-party compliance testing and multi-unit remote control.

Scenarios Prioritizing G-Pro Gradient Version

Primer annealing temperature development & multi-temperature parallel gradient screening (core exclusive function unavailable on basic model).
Third-party testing & pharmaceutical R&D labs requiring traceable experimental data, GLP compliance and hierarchical staff permission management.
Labs with multiple PCR instruments needing unified remote monitoring via single PC LAN.
Regular complex biochemical workflows including Touchdown PCR, Long PCR, constant-temperature enzyme digestion & incubation.
Mass standardized lab SOPs requiring massive local storage of thousands of protocols, fast USB program copy & raw data export.
Overseas research institutes & key university labs pursuing lightweight body, high-resolution screen and convenient USB firmware upgrade.

Application Scenarios

1. Research Laboratories: Primer annealing gradient screening, long-fragment gene cloning, site-directed mutation verification, Touchdown PCR, constant-temperature enzyme incubation.
2. Universities & Education: Postgraduate molecular research projects, gradient method development training, high-throughput amplification in key labs.
3. Pharmaceutical & Chemical: New drug target primer condition optimization, gradient microbial identification of API raw materials, gene expression quantification of intermediates.
4. Food, Environmental & Industrial Testing: Multi-temperature pathogen screening, precise genotyping of trace water microorganisms, condition exploration for industrial strains.
5. Medical & Healthcare: Gradient nucleic acid preliminary screening of clinical pathogens, cell constant-temperature incubation, multi-condition parallel amplification of research specimens.
6. Semiconductor & Electronics: Gradient microbial QC detection of high-purity process reagents, nucleic acid auxiliary verification for biochip manufacturing.
7. Textile & Leather: Molecular traceability of functional microbial strains for textile & leather bio-finishing, gradient identification of dye-degrading bacteria.
  • Shockproof packaging: Thickened export wooden crate with integrated high-density shock-absorbing foam separating thermal cycler main unit, power cord and user manual to avoid collision damage during long sea & land transit; reinforced crate as default for bulk export orders.
  • Full package contents: L1000TC-G-Pro gradient thermal cycler main unit, AC global wide-voltage power cord, printed factory full user manual, factory gradient temperature precision quality inspection certificate.
  • Reference package dimension & weight: Outer crate approx 340×430×310mm, unit net weight 9.5kg, full set gross weight 11.6kg.
  • Lead time rule: In-stock standard models ship within 3–10 working days; orders with pre-set custom gradient programs, multi-language UI and bulk authorized PC control software take 15–30 working days.
  • Logistics options: Sea freight, air freight and LTL road transport available, dedicated logistics line for bulk overseas export of high-end molecular research & testing instruments.

Selling Units

Single item

Package size perbatch

56*40*39cm

Gross weight perbatch

11.6kg

 

 

Accessory Name Qty
Main Unit 1 unit
Power Cable 1 pc
User Manual 1 copy
Packing List / Certificate of Conformity 1 set
Warranty Card 1 copy
Contact customer service to receive full documents: Complete L1000TC-G-Pro gradient datasheet, WIFI multi-unit remote control manual, gradient program editing & calibration guide, dimension drawings, product brochure and factory well uniformity & gradient accuracy inspection report for tender archive of research institutes, pharmaceutical factories and third-party testing labs.

  • What are the core differences between gradient L1000TC-G-Pro and non-gradient standard thermal cyclers?
    This unit supports adjustable continuous gradient difference 1–42℃ with independent zone control, multiple annealing temperatures can be set on one plate for batch screening of optimal primer conditions. Non-gradient models only provide uniform single temperature across the whole block and cannot run parallel multi-gradient exploration trials, only suitable for fixed mature amplification protocols.
  • What is the maximum adjustable gradient difference, and how to disable gradient function?
    Gradient difference adjustable range 1–42℃; input digit 0 in program parameters to directly turn off zone gradient control and switch to single uniform temperature mode.
  • What is the maximum heating & cooling rate, and temperature control performance?
    Max ramp rate reaches 5℃/sec; temperature display accuracy ±0.1℃, well-to-well uniformity ±0.2℃ at 55℃, edge temperature compensation technology minimizes temperature deviation of peripheral wells.
  • Which PCR consumables are compatible, does it support different skirt types of 96-well plates?
    Fully compatible with standard 0.2mL labware: individual single tubes, 8-strip tubes and three variants of 96-well microplates (skirtless / semi-skirted / fully skirted), no extra adapter required for mainstream commercial consumables.
  • If power cuts off mid-run, do I need to restart the full program from beginning after power recovery?
    Built-in auto power-off resume protection; the instrument automatically resumes cycles from the interrupted position after power is restored, no manual full re-run required.
  • Can one single computer synchronously control multiple gradient PCR instruments?
    Built-in WIFI communication module connects to PC host via LAN, one computer can simultaneously monitor, edit and run amplification programs on multiple units, ideal for high-throughput batch labs.
  • How many program files can be stored, and how to export backup?
    The unit supports storage of over 20000 custom amplification programs via U-disk; all programs can be exported to flash drive for archiving after experiments, local firmware upgrade via U-disk is also available.
  • What is the display configuration, is the operation interface easy to learn?
    7-inch 1024×600 color capacitive touch LCD screen with new graphical UI menu and visual workflow; new operators can finish gradient & cycle programming quickly.
  • What is the adjustable lid temperature range and its function?
    Heated lid adjustable from 30–115℃; temperature can be tuned according to kits and sample systems to prevent water vapor condensation on lid wall and avoid sample evaporation loss during amplification.
  • Does it support special Long PCR and Touchdown PCR modes?
    Pre-set built-in experimental modes: Touchdown temperature offset -9.9℃~+9.9℃, Long PCR duration range -9min59s~+9min59s, optimized for large fragment genes and difficult-to-anneal primer amplification trials.
  • Is there a one-touch rapid incubation function, what experiments is it applicable to?
    One-key quick incubation shortcut available for nucleic acid denaturation, enzyme digestion & ligation, ELISA immuno-incubation and other constant-temperature basic biochemical experiments.
  • Can hierarchical user accounts and operation passwords be created?
    Multiple user accounts with independent login passwords can be created to separate program read/write & edit authority for different operators, convenient for experimental traceability management in compliance labs.
  • Does the wide voltage fit overseas 110V labs?
    Auto-adaptive wide voltage 100~120V / 200~240V 50/60Hz, European, American and Southeast Asian overseas labs can run directly without extra transformer.
  • Can the aluminum heating block be purchased separately for replacement later?
    Aluminum adapter block is standard core component, original spare parts can be ordered individually for later replacement; sealing and silicone consumables are also available as separate spare parts.
  • What is the minimum and maximum temperature range of the heating block?
    Heating block covers 0–105℃, independent heated lid temperature 30–115℃, covering full temperature demands of standard PCR, enzyme incubation and constant-temperature microbial culture workflows.

  • Provide order quantity, destination country and bulk PC control software license demand to receive tiered bulk discount quotation
  • Free customized full molecular lab matching scheme for institute primer gradient screening & third-party compliance testing labs, official PI issued within 24 working hours
  • Exclusive tiered discounted pricing available for bulk procurement from university key labs, pharmaceutical enterprises and large third-party testing institutes
Applications 应用场景模块

Applications

Applications

Supporting diverse laboratory and industrial environments with practical instrument solutions.

Research Laboratories

Research Laboratories

For DNA amplification, gene cloning, sequencing and primer temperature optimization in molecular biology research.

Universities and Education

Universities & Education

Basic molecular experiment equipment for genetics, biotechnology teaching and student training..

Pharmaceutical and Chemical

Pharmaceutical & Chemical

Genetic testing of raw materials, microbial strain identification and biopharmaceutical gene analysis.

Food Environmental and Industrial Testing

Food, Environmental & Industrial Testing

Detect food pathogens, transgenic ingredients and environmental microbial nucleic acid samples.

Leave a message
Name *
Email *
Whatsapp/Phone
Message *
Verification Code *
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.