• Thermal Cycler Standard laboratory routine PCR gene amplification equipment
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler Standard laboratory routine PCR gene amplification equipment
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.

Thermal Cycler Standard

No.L1000TC-S
The L1000TC-S Thermal Cycler Standard is a basicinstrument for molecular laboratories and is widely usedin gene detection, molecular cloning, gene expression,mutagenesis, and other applications in fields such asdrug discovery, agriculture, and the food industry

The Labcarta Standard Thermal Cycler delivers precise thermal cycling with advanced temperature control, supporting PCR tubes, strips, and plates. This standard thermal cycler is ideal for molecular labs and a trusted pcr thermal cycler supplier.

$6434.30
Model:
L1000TC-S
  • Thermal Cycler Standard laboratory routine PCR gene amplification equipment
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Thermal Cycler StandardIlabcarta Technology Co., Ltd.
  • Description

  • Key Features

  • Parameter

  • Product Details

  • How to Choose

  • Packaging & delivery

  • Download

  • FAQ

  • Get a Quote

L1000TC-S Standard Thermal Cycler is a basic temperature-controlled amplification instrument for molecular biology labs. It is widely applied in gene detection, molecular cloning, gene expression, site-directed mutagenesis and other routine molecular experiments, covering drug discovery, agricultural breeding, food microorganism testing, university molecular teaching and other fields.
The instrument is compatible with three mainstream consumables: 96×0.2mL single PCR tubes, 12 strips of 8×0.2mL PCR tubes, and 96-well 0.2mL PCR microplates. Temperature range reaches 4–105℃, while the independent heated lid ranges 30–110℃. Temperature display accuracy is ±0.1℃, well-to-well uniformity <0.3℃ at 55℃, with a maximum heating/cooling rate of 5℃/sec. It adopts aluminum heating block and high-performance thermoelectric semiconductors for temperature control, equipped with edge temperature compensation technology to deliver excellent well uniformity. A 7-inch 800×480 color touch panel supports both block & tube control modes. Up to 30 program segments and 99 cycles can be edited, with storage capacity for over 200 custom experimental protocols. Built-in power-off protection automatically resumes unfinished programs after power recovery. It supports Touchdown PCR (-9.9℃ ~ +9.9℃) and Long PCR (-9min59s ~ +9min59s), plus auto heated lid closing function (lid shuts automatically when block temperature below 30℃). Compact dimension 280×370×250mm with net weight 11kg, universal dual voltage 100~120V/200~240V for global labs. It serves as the standard entry-level PCR device for mid-budget labs conducting routine ordinary amplification assays.

  • High-performance thermoelectric semiconductor temperature control system: Precise zonal regulation combined with edge temperature compensation technology minimizes well-to-well temperature difference, delivering <0.3℃ uniformity at 55℃ and highly repeatable amplification results.

  • Full compatibility with standard PCR consumables: Works with 0.2mL single tubes, 8-strip tubes and 96-well microplates without block replacement for different sample carriers.

  • Supports two special amplification assays: Touchdown PCR (±9.9℃ gradient) and Long PCR (-9min59s ~ +9min59s extension) for general cloning and long-chain gene amplification.

  • 7-inch high-definition color touch screen: Full-touch visual program editing with intuitive workflow, enabling untrained lab staff to create amplification protocols quickly.

  • Large local program storage: Each protocol supports up to 30 temperature segments and 99 amplification cycles; the unit stores over 200 independent experimental methods for one-click recall of repeated tests.

  • Power-off protection & auto program recovery: After unexpected power cut, the instrument reloads interrupted protocols automatically on reboot to avoid sample waste and repeated testing.

  • Intelligent auto heated lid closing: The lid shuts automatically when block temperature drops below 30℃ to cut manual operations and prevent sample loss via evaporation & condensation.

  • Dual selectable control modes: Block bulk temperature control and precise single-tube control, matching high-throughput screening and micro fine amplification respectively.

  • Global wide adaptive voltage input: 100~120V/200~240V 50/60Hz universal supply, no extra transformer required for overseas lab deployment.

  • Compact lightweight desktop design: Net weight only 11kg with minimal bench footprint, ideal for mass placement in university teaching labs and small third-party testing institutes.

Category Parameter Item L1000TC-S Specification
Sample Loading Compatible Consumables 96×0.2mL single PCR tubes, 12×0.2mL 8-strip tubes, 0.2mL 96-well microplates (skirtless/semi/fully skirted)
Temp Performance Heating Temp Range 4–105℃
Lid Temp Range 30–110℃
Temp Display Accuracy ±0.1℃
Well Uniformity @55℃ <0.3℃
Max Heating/Cooling Rate 5℃/sec
Gradient Function No gradient zone setting function
Program System Max Segments Per Program 30 segments
Total Storable Programs Over 200 user-defined programs
Control Method Thermoelectric semiconductor PID control with edge temperature compensation
HMI Interface Display 7-inch color touch LCD 800×480
Input Mode Touch-only panel, no physical buttons
Mechanical Structure Lid Function Auto lid closing when block temp <30℃
Block Material Aluminum alloy
Safety Features Power-off Protection Auto resume unfinished cycles after power recovery
Communication Expansion Host Computer System No built-in upper computer control system
Communication Ports No USB, WIFI interfaces
Power Spec Voltage/Frequency Auto-adaptive 100~120V/200~240V 50/60Hz
Dimension & Weight Overall Size(W×D×H) 280×370×250mm
Net Weight 11kg
Ambient Condition Permissible Temp 5–40℃
Permissible Humidity ≤80%RH non-condensing
Protection Class IP Rating IP20
  • Sample loading & dispensing: Dispense DNA/RNA template, primers and enzyme mixture into 0.2mL PCR tubes / 96-well plates, seal tubes to prevent evaporation, then place evenly into aluminum heating block.
  • Power-on program recall / editing: Boot the unit after connecting universal voltage power supply, 7-inch touch screen completes self-check. Users may directly recall mature protocols stored in the 200-program library, or create new programs with up to 30 temperature segments and customized cycle counts.
  • Experiment mode selection: Switch between Block bulk control (high-throughput batch samples) or Tube single-tube precise control (trace precious samples) as required, set heated lid temperature 30–110℃ to eliminate condensation.
  • Start amplification reaction: Tap Run after verifying all parameters. The heated lid closes automatically when block temperature falls below 30℃, and the instrument completes denaturation, annealing and extension cycles at the set heating/cooling rate.
  • Power failure emergency recovery: If power cuts off mid-experiment, the unit automatically loads the interrupted program after power restoration and continues remaining cycles without re-preparing samples.
  • Post-test sample retrieval: After all cycles finish, wait for the block to cool down to safe temperature, take out PCR tubes/plates, power off the main unit and wipe residual reagents from the heating block.


Model Position Differentiation
L1000TC-S is a gradient-free standard basic thermal cycler without gradient temperature function. It fits labs that only run mature fixed amplification protocols without primer annealing temperature optimization. Select gradient-suffix models if annealing temperature gradient screening is required.

Eligible Experiment Screening

Routine basic amplification: General gene cloning, microbial identification, preliminary gene expression quantification, university molecular biology teaching training, fully supported by this unit.
Special amplification compatibility: Touchdown PCR and Long PCR for long-chain plasmid & large fragment gene amplification.
Unsuitable workflows: Primer annealing temperature gradient screening, parallel multi-temperature condition exploration (gradient model required).

Budget & Consumable Comparison

Cost advantage: Lower procurement cost for gradient-free basic version, ideal for budget-limited universities and small third-party testing labs.
Consumable compatibility: Fully compatible with mainstream 0.2mL single tubes, 8-strip tubes and 96-well plates, no extra cost for proprietary consumables.
Global power adaption: Dual wide auto-adaptive voltage eliminates the need for external transformers for overseas lab shipment.

Application Scenarios

  1. Research Laboratories: Routine gene amplification with mature protocols, long-fragment plasmid cloning, site-directed mutation verification, Touchdown PCR assays
  2. Universities & Education: Undergraduate molecular biology teaching, basic gene amplification training, graduation project standard PCR
  3. Pharmaceutical & Chemical: Drug target gene cloning, strain identification, microbial contamination test of API raw materials
  4. Food, Environmental & Industrial Testing: Pathogen PCR identification in food, water microorganism screening, industrial strain genotyping
  5. Medical & Healthcare: Preliminary pathogen nucleic acid screening, routine gene amplification of clinical specimens, gene expression detection of research cells
  6. Semiconductor & Electronics: Microbial quality control of high-purity reagents, supporting basic nucleic acid amplification for biochips
  7. Textile & Leather: Microbial traceability of printing & dyeing wastewater, molecular identification of raw material strains
  • Shockproof packaging: Thickened export wooden crate with integrated high-density shock-absorbing foam separating thermal cycler main unit, power cord and user manual to avoid collision damage during long sea & land transit; reinforced crate as default for bulk overseas orders.

  • Full package contents: L1000TC-S thermal cycler main unit, AC wide-voltage power cord, printed factory user manual, factory temperature accuracy quality inspection certificate.

  • Reference package dimension & weight: Outer crate approx 340×430×310mm, unit net weight 11kg, full set gross weight 14.5kg.

  • Lead time rule: In-stock standard models ship within 3–10 working days; orders with pre-set custom experimental programs or multi-language UI customization take 15–30 working days.

  • Logistics options: Sea freight, air freight and LTL road transport available, dedicated logistics line for bulk export of molecular biology teaching & testing instruments.

Selling Units

Single item

Package size perbatch

56*40*39cm

Gross weight perbatch

11.6kg

 

Accessory Name

Qty

Main Unit

1 unit

Power Cable

1 pc

User Manual

1 copy

Packing List / Certificate of Conformity

1 set

Warranty Card

1 copy

Contact customer service to receive full documents: Complete L1000TC-S datasheet, thermal cycler program editing & calibration manual, dimension drawings, product brochure and factory temperature uniformity inspection report for tender archive of university and third-party testing lab equipment.

  • What are core differences between L1000TC-S standard and gradient L1000TC-G-Pro?
    ①Gradient function: S model has no zone gradient control and cannot run parallel annealing screening; G-Pro supports adjustable 1–42℃ gradient difference.
    ②Display: S model 7-inch basic 800×480 screen; G-Pro high-definition 1024×600 touch screen.
    ③Communication expansion: S without USB/WIFI, no PC linkage or U-disk program access; G-Pro supports WIFI multi-unit control, U-disk data export and firmware upgrade.
    ④Program storage: S only stores 200 programs; G-Pro stores over 20000 sets.
    ⑤Net weight: S unit 11kg, gradient G-Pro 9.5kg.
    ⑥Experiment matching: S only for fixed mature standard PCR; G-Pro for R&D gradient exploration and networked multi-instrument labs.
  • Can L1000TC-S run gradient PCR to screen annealing temperatures?
    No, this unit has no independent zone gradient control, the whole heating block only maintains one uniform temperature, multiple parallel annealing conditions cannot be set at the same time for gradient screening. Select L1000TC-G-Pro gradient model if gradient trials are required.
  • Can the screen connect to a computer to control multiple thermal cyclers simultaneously?
    L1000TC-S has no WIFI or USB communication ports and no built-in host control system, it does not support PC linkage, synchronous multi-unit management, U-disk program export or firmware upgrade.
  • How many custom amplification programs can be stored at maximum, and how many temperature segments per single program?
    The unit can store up to 200 complete experimental programs; each single program supports a maximum of 30 independent temperature segments to meet long-duration multi-stage amplification workflows.
  • Will the heated lid close automatically when block temperature drops below 30℃?
    Yes, built-in auto lid closing mechanism will close the lid automatically once the heating block temperature is detected below 30℃ to simplify manual operation steps.
  • Do I need to restart the whole program from the beginning after sudden power cut?
    Equipped with auto power-off resume protection, the unit automatically continues interrupted amplification cycles after power recovery without full manual re-run.
  • Does it support Touchdown PCR and Long PCR experiments?
    Yes, two dedicated pre-set amplification modes are integrated: Touchdown temperature offset range -9.9℃~+9.9℃, Long PCR duration range -9min59s~+9min59s.
  • Which PCR consumables are compatible, can different skirt types of 96-well plates be used?
    Fully compatible with standard 0.2mL labware: single PCR tubes, 8-strip tubes and skirtless / semi-skirted / fully skirted 96-well microplates without extra adapter fittings.
  • What is the minimum and maximum temperature of the heating block, and adjustable lid range?
    Heating block temperature range 4–105℃; independent lid temperature adjustable from 30–110℃, lid temp can be tuned according to kits to avoid sample condensation & evaporation.
  • What is the well-to-well uniformity index under 55℃ constant temperature?
    Under 55℃ platform, overall well-to-well temperature uniformity is less than 0.3℃, edge temperature compensation technology reduces temperature deviation of peripheral wells.
  • What maximum heating and cooling rate can the unit reach?
    The maximum unified heating & cooling rate reaches 5℃/sec, meeting fast amplification demands of standard regular PCR experiments.
  • Does the voltage support direct use in overseas 110V labs?
    Auto-adaptive wide voltage 100~120V/200~240V compatible with 50/60Hz, overseas 110V labs can run directly without external voltage transformer.
  • What type of labs is this model suitable for procurement?
    Ideal for university basic molecular teaching labs, small labs and routine third-party screening institutions that only run mature fixed standard PCR, have no gradient screening demands, do not require PC online control and have limited budget.

  • Provide order quantity, destination country and custom pre-program demand to receive tiered bulk discount quotation
  • Free customized routine PCR matching scheme for university molecular teaching and small third-party testing labs, official PI issued within 24 working hours
  • Exclusive discounted pricing available for bulk procurement from vocational schools, food & environmental testing laboratories
Applications 应用场景模块

Applications

Applications

Supporting diverse laboratory and industrial environments with practical instrument solutions.

Research Laboratories

Research Laboratories

For DNA amplification, gene cloning, sequencing and primer temperature optimization in molecular biology research.

Universities and Education

Universities & Education

Basic molecular experiment equipment for genetics, biotechnology teaching and student training..

Pharmaceutical and Chemical

Pharmaceutical & Chemical

Genetic testing of raw materials, microbial strain identification and biopharmaceutical gene analysis.

Food Environmental and Industrial Testing

Food, Environmental & Industrial Testing

Detect food pathogens, transgenic ingredients and environmental microbial nucleic acid samples.

Leave a message
Name *
Email *
Whatsapp/Phone
Message *
Verification Code *
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.