• Touch screen single beam Visible spectrophotometer for lab colorimetric spectral analysis
  • Touch screen single beam Visible spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen single beam Visible spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen single beam Visible spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen single beam Visible spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen single beam Visible spectrophotometer for lab colorimetric spectral analysis
  • Touch screen single beam Visible spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen single beam Visible spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen single beam Visible spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen single beam Visible spectrophotometerIlabcarta Technology Co., Ltd.

Touch screen single beam Visible spectrophotometer

No.LSP2-1101-UV
The LSP2-1101-UV is designed for laboratories in chemicalanalysis, life sciences, environmental testing, and industrialquality control. It is ideal for research institutions, educationalfacilities, and production labs that require precise andefficient visible spectrum analysis. Its intuitive touch-screeninterface enhances usability, making it suitable for bothroutine testing and complex analytical applications.
$4013.20
Model:
LSP2-1101-UV
  • Touch screen single beam Visible spectrophotometer for lab colorimetric spectral analysis
  • Touch screen single beam Visible spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen single beam Visible spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen single beam Visible spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen single beam Visible spectrophotometerIlabcarta Technology Co., Ltd.
  • Product Overview

  • Key Features

  • Parameter

  • Product Details

  • How to Choose

  • Packaging & delivery

  • Download

  • FAQ

  • Get a Quote

LSP2-1101-UV touchscreen single beam UV Vis spectrophotometer targets university research training labs, micro testing rooms of small & medium enterprises, grassroots third-party precision screening institutes and basic R&D departments of new chemical material manufacturers for postgraduate trainees, micro lab technicians and basic R&D testing operators. It addresses pain points of economical single-beam instruments including insufficient resolution for micro samples caused by wide spectral bandwidth, tiny traditional display screen, mandatory optical calibration after deuterium-tungsten lamp replacement, lack of complete GLP data traceability for micro detection, limited compatible accessories for micro samples and complicated data export workflow for batch micro testing.
Adopting single-beam optical system with 1200 lines/mm grating and narrow 1.0nm high-resolution spectral bandwidth, pluggable imported deuterium & tungsten dual light source and imported silicon photodiode detector, it covers full UV-Vis wavelength range 190–1100nm. Equipped with 10.1-inch 1024*600 TFT capacitive color touch screen and intuitive Windows graphical interface, the unit has 1024M large built-in local memory. It integrates six core high-precision analysis modes: photometric measurement, high-accuracy micro quantitation, fine kinetics scanning, high-resolution full spectrum scan, micro-volume DNA/protein quantification and multi-wavelength synchronous fine detection. Triple data output ports (USB storage, USB PC host, RS232 serial) support one-click Excel export for micro test data. Complete basic GLP/GMP recording functions include multi-level account management, full operation logs and full-chain traceability of micro detection data. Standard configuration includes 10mm manual 4-cell holder, with optional expandable accessories such as auto cell changer, thermostatic autosampler, micro cell mount, reflection accessory and integrating sphere. It shares identical body dimension and standard accessories with the full product series, serving as a cost-effective precision instrument for budget-limited labs with micro and low-concentration sample testing demands.
  • 1.0nm narrow high-resolution single-beam optical system: 1200 lines/mm grating with stray light ≤0.03%T and flat stable baseline, delivering far superior resolution for micro, low-concentration and trace samples compared to 2.0nm bandwidth economical models to meet basic precision quantitation requirements.
  • Imported socket-type deuterium & tungsten dual light source: Standard UV-Vis combined lamp set with calibration-free plug holder; lamp replacement requires no professional optical debugging, allowing independent maintenance by grassroots micro lab staff.
  • 10.1-inch high-definition capacitive color touch screen: 1024*600 Windows visual graphical interface enables untrained postgraduates and technicians to master the full workflow of micro fine scanning and data export efficiently.
  • Six integrated high-precision micro analysis programs: Compatible with photometry, micro quantitation, fine kinetics, high-resolution spectrum scanning, micro-volume DNA/protein test and multi-wavelength fine analysis for screening of micro biological samples, low-concentration chemical raw materials and trace environmental pollutants.
  • 1024M massive internal memory: Mass storage for high-resolution micro spectra, low-concentration calibration curves and batch raw micro test data to cut frequent USB backup operations.
  • Complete basic GLP/GMP audit traceability module: Multi-tier account permission, full operation logging and full traceability for every set of micro test data to satisfy basic export audit standards of food and general pharmaceutical enterprises.
  • Multi-channel micro data export solution: Offline USB storage, USB PC connection and RS232 serial communication support one-click Excel export for micro experimental data to rapidly generate compliance test reports.
  • Series universal micro-compatible optional accessories: Auto cell holder, thermostatic autosampler, micro cell mount, reflection accessory and integrating sphere share consumables with LSP3 & LSP5 series, eliminating full accessory replacement for later upgrades.
  • Imported silicon photodiode ultra-low noise detector: Noise as low as 0.0005A with high sensitivity for faint signal capture, delivering stable and reliable repeatability for micro low-concentration sample detection.
  • Triple adjustable scanning speeds: High/Med/Low modes up to max 3000nm/min, balancing fast batch screening of micro samples and slow fine spectrum scanning for research experiments.
Specifications LSP2-1101-UV
Optical System Single Beam, Grating 1200 lines/mm
Wavelength Range 190-1100 nm
Spectral Bandwidth 1.0nm
Wavelength Accuracy ±0.1nm (at 656.1nm), ±0.3nm @all
Wavelength Repeatability ≤0.1nm
Photometric Accuracy 0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A)
Photometric Repeatability ≤0.15%T(0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A)
Photometric Range 0-200%T, -0.3~3A, -0.9999C(-0.9999F)
Stray Light ≤0.03%T @ 220,360nm
Stability ±0.0003A/h @500 nm
Baseline Flatness ±0.001A
Noise 0.0005A@500nm
Work Mode T, A, C, E
Scanning Speed Hi, Med, Low (Max.3000nm/min)
Wavelength Setting Auto
Display 10.1" TFT Colored Capacitive Touch Screen
Light Source Imported Deuterium & Tungsten lamp
Detector Imported Silicon Photodiode
Cuvette Holder 10mm manual 4-cell holder
Output USB drive, USB host, RS232
Power Requirements AC 220V/50Hz or AC 110V/60Hz
Dimension[L×W×H] 570mm×440×210mm
Weight 20kg
Standard Accessories 10mm glass cuvette × 4, 10mm quartz cuvette × 2, Power cord, User's Manual , PC software
  • Power-on warm-up: Connect AC power and boot the unit, deuterium & tungsten lamps ignite automatically, full system self-check runs, sufficient warm-up eliminates minor baseline drift to guarantee detection precision for micro low-concentration samples.
  • Micro experiment mode configuration: Select high-precision micro analysis mode via 10.1” touch screen (micro quantitation / high-res spectrum scan / fine kinetics scan / micro DNA-protein test), customize slow fine scanning, narrow-band wavelength range and micro data storage parameters.
  • High-accuracy baseline correction: Fill blank reference solution into 10mm quartz cuvette and place into 4-cell holder, run baseline correction program; single-beam optical path accurately compensates faint background interference for trace sample testing.
  • Micro sample spectrum measurement: Insert micro test samples sequentially and start single-point high-precision test or slow high-resolution spectrum scan; the unit captures extremely low photometric signals with delicate high-resolution spectral curves and readings displayed on screen in real time.
  • Micro data storage & export: All high-res micro spectra and low-concentration calibration curves auto-saved to 1024M memory; plug in USB flash drive for one-click Excel export after experiment, or transmit data via USB/RS232 to matched PC software for research graph plotting and generation of basic GLP compliance test reports.
  • Shutdown maintenance: Take out micro cuvettes, fully rinse with ultrapure water and air-dry, turn off lamp and main power; disconnect power supply for long idle storage, gently wipe optical window to prevent dust accumulation which reduces micro detection sensitivity.

Key Factors to Help You Pick the Right Model

  1. Bandwidth, optical path & budget tier distinction
  • Only basic teaching, routine high-concentration batch rough screening and extremely limited budget: LSP2-1102-UV (2.0nm single-beam entry-level cost-effective model);
  • Labs with micro, low-concentration and trace sample testing demands but unable to afford double-beam instruments due to budget constraints: Prioritize this LSP2-1101-UV (1.0nm narrow resolution single-beam);
  • Uninterrupted long-time micro scanning, full-chain audit for pharmaceutical export and ultra-high baseline stability requirements: Upgrade to LSP3 (double-beam deuterium-tungsten) / LSP5 (double-beam long-life xenon) series.
  1. Light source operation scenario distinction
  • Intermittent testing and mature supply channels for lab deuterium-tungsten consumables: All LSP2 & LSP3 deuterium-tungsten models;
  • 7×24h high-frequency continuous micro testing with demand for less lamp replacement: LSP5 long-life xenon lamp series.
  1. Compliance audit grade distinction
  • Small & medium food, chemical factories and grassroots third-party labs only requiring complete basic GLP record traceability: Built-in module of LSP2-1101-UV fully meets demands;
  • Export pharmaceutical factories, health food and overseas third-party precision testing institutes: Select LSP3/LSP5 models with full-chain complete GLP/GMP audit system.
  1. Expandability demand for micro special samples
    Testing of micro biological body fluid, low-concentration constant-temperature kinetics and new solid diffuse reflection materials: Full optional expandable accessories supported (No accessory model / part number printed on original brochure, links & specs can be supplemented after factory data update). Accessories are compatible with full product series with no separate dedicated micro equipment purchase required.
  2. Multi-user shared scenario for teaching & small R&D labs
    Postgraduate training in colleges and universities, R&D labs of small & medium enterprises: Intuitive 10.1-inch large touch screen operation cuts training cost for untrained personnel.

Matching Application Scenarios (9 Standard Categories)

  1. Research Laboratories: Low-concentration kinetic mechanism study, micro spectrum of new materials, simple precise analysis of trace water pollutants
  2. Universities & Education: Postgraduate micro project training for chemistry/biology majors, advanced precise teaching experiments for undergraduates
  3. Pharmaceutical & Chemical: Rough screening of micro impurities in API of small & medium pharmaceutical factories, quantitation of low-concentration fine chemical products
  4. Food, Environmental & Industrial Testing: Trace heavy metals test for township environmental stations, micro food additive screening for small food factories, low-concentration raw material QC for manufacturers
  5. Medical & Healthcare: Simple quantitation of protein & nucleic acid in micro biological samples for grassroots medical institutions
  6. Semiconductor & Electronics: Micro impurity detection of cleaning fluid for small & medium electronics factories
  7. Textile & Leather: Determination of micro dye residues in waste water of small printing & dyeing factories
  8. Automotive: Basic analysis of micro lubricant additives and trace corrosive media in coolant
  9. Aerospace: Simple detection of micro impurities in special solvents for small supporting enterprises
  • Shockproof packaging solution: Multi-layer thick reinforced export wooden crate with integrated high-density shock-absorbing foam separating precision optical main unit, glass/quartz micro cuvettes, power cord and software CD to avoid breakage & collision during long sea & land transit; thickened solid wooden crate as default for bulk overseas orders.

  • Full set package contents: LSP2-1101-UV spectrophotometer main unit, 4 pcs 10mm glass cuvette, 2 pcs 10mm high-transmittance quartz micro cuvette, AC power cord, printed factory user manual, PC spectrum analysis software CD, factory quality inspection certificate.

  • Reference package dimension & weight: Single full-set outer crate 62×49×28cm, gross weight 24kg per unit.

  • Lead time: In-stock standard models ship within 3–10 working days; custom exclusive wavelength range, full expandable accessory bundle and customized software UI orders take 15–30 working days.

  • Logistics options: Sea freight, air freight and full-truck land transport available, dedicated logistics line for bulk overseas export of economical micro detection lab instruments.

Selling Units

Single item

Package size perbatch

60*48*37cm

Gross weight perbatch

24kg

 

Name

Qty

Main Unit

1

Power Adapter

1

User Manual

1

Certificate of Conformity

1

Warranty Card

1

Dust Cover

1

Sample Cell Holder (10mm, 4‑cell)

1

Quartz Cuvette (1cm)

2

Glass Cuvette (1cm)

2

USB Data Cable

1

RS232 Data Cable

1

Software CD / USB Drive

1

Contact customer service to receive full documents: Integrated complete technical datasheet, full calibration & operation manual for micro precision detection instrument, dimension drawings, product brochure, factory inspection report and basic GLP/GMP compliance operation guide for tender archive of postgraduate training labs in universities and micro testing labs of small & medium enterprises.

  • What are core upgraded differences between LSP2-1101-UV and previous LSP1102-UV gradient model?
    ①Optical grating: Upgraded to 1200 lines/mm grating with 1.0nm bandwidth (2.0nm for old model), overall improved wavelength accuracy, stray light and noise performance.
    ②Display: 10.1-inch large capacitive touch screen vs small dot matrix LCD of old version.
    ③Storage: Built-in massive 1024M local memory, old model only stores 4000 test records.
    ④Compliance: Native full GLP/GMP support for multi-level accounts, audit logs and data traceability, no complete compliance system on old equipment.
    ⑤Communication: New RS232 serial port added, triple USB/USB host/RS232 outputs vs only USB + parallel print on old model.
    ⑥20kg heavy-duty optical bench for superior stability, compatible with high-end research accessories such as integrating sphere and auto sampler.
  • What is the spectral bandwidth, what advantages for trace low-concentration samples?
    Ultra-narrow 1.0nm spectral bandwidth matched with 1200-line precision grating, ultra-low stray light ≤0.03%T and ultra-low noise 0.0005A, drastically reducing background deviation of peripheral wells, delivering outstanding accuracy and parallel repeatability for trace low-dose nucleic acid & drug specimens compared with 2.0nm bandwidth instruments.
  • What is the full wavelength range and light source configuration?
    Full UV-NIR band 190–1100nm; imported dual deuterium & tungsten lamp sources with pluggable socket design, lamp replacement without optical re-calibration for simple maintenance.
  • What is the local storage capacity, does it meet GLP/GMP audit standards?
    Built-in massive 1024M local flash memory for mass storage of standard curves and test data; native support for multi-level user accounts, independent operation passwords, complete run logs and full traceable raw data export, fully satisfying GLP/GMP compliance audit requirements of pharmaceutical factories and third-party testing labs.
  • How many data output ports are equipped, what are their respective purposes?
    Triple communication outputs: ①USB flash drive for offline local storage, data export and firmware upgrade; ②USB host to connect PC upper software for multi-unit synchronous control; ③RS232 serial port to link industrial automation equipment and external control systems.
  • What consumables come as standard, what optional research accessories are available?
    Standard included: 4×10mm glass cuvettes, 2×10mm quartz cuvettes, power cord, printed user manual, PC analysis software.
    Optional research extras: auto thermostatic cell holder, fully automatic sampler, micro cell rack, reflectance integrating sphere, variable optical path solid sample holder.
  • What experimental modes are supported, can it run DNA/protein and kinetic scanning?
    Four basic T/A/C/E work modes; pre-set dedicated programs for photometric quantitation, long-duration kinetics, full spectrum scan, simultaneous multi-wavelength detection and Touchdown nucleic acid protein analysis, supporting high-speed spectrum acquisition up to 3000nm/min.
  • How many scan speed grades are available, what is the maximum scan rate?
    Three adjustable high/medium/low auto scan grades with maximum scan speed 3000nm/min, drastically cutting full-band spectrum acquisition time.
  • What are the indexes of stray light, noise and photometric stability?
    Stray light ≤0.03%T @220/360nm; ultra-low noise 0.0005A @500nm; photometric stability ±0.0003A/h after 2h preheat with minimal drift during long continuous scanning.
  • Will experimental data be lost after sudden power cut?
    Built-in large-capacity local flash memory automatically saves all curves, operation logs and raw test records during power failure, complete file recall available after power recovery without full program re-run.
  • What is the display specification, is the operation interface user-friendly?
    10.1-inch 1024×600 color capacitive touch large screen with Windows graphical menu and visual workflow logic, easy for new operators to master and more comfortable vision during long experiments.
  • Does the wide voltage fit overseas 110V labs?
    Auto-adaptive AC 110V/60Hz or AC 220V/50Hz, European, American and Southeast Asian overseas labs can run directly without external voltage transformer.
  • What cell holder comes as standard, what size cuvettes are compatible?
    Standard 10mm manual 4-position cell holder compatible with mainstream commercial standard 10mm glass & quartz cuvettes; micro accessories can be added for semi-micro trace sample testing.
  • Is light source replacement complicated, does professional optical debugging required?
    Socket plug-and-play lamp design, directly swap deuterium/tungsten lamp without engineer on-site optical calibration to reduce after-sales maintenance cost.
  • What type of labs is this unit suitable for procurement?
    New drug R&D institutes, key molecular biology labs, large pharmaceutical QC centers, third-party compliance testing organizations, university research institutes and high-precision trace environmental pollutant analysis labs.

  • Provide order quantity, destination country and optional expandable accessories / custom wavelength demand to receive tiered bulk discount quotation
  • Free customized matching scheme for university micro research and small enterprise precision screening labs, official PI issued within 24 hours
  • Exclusive discounted pricing available for bulk procurement from colleges, small & medium food / environmental testing factories
Applications 应用场景模块

Applications

Applications

Supporting diverse laboratory and industrial environments with practical instrument solutions.

Research Laboratories

Research Laboratories

Conduct SDS-PAGE protein separation, nucleic acid electrophoresis and molecular specimen analysis for life science research..

Universities and Education

Universities & Education

Complete protein & gene electrophoresis experiments for biotech, biology and chemistry course training.

Pharmaceutical and Chemical

Pharmaceutical & Chemical

Analyze target protein, separate biological ingredients and test biopharmaceutical sample purity.

Food Environmental and Industrial Testing

Food, Environmental & Industrial Testing

Identify microbial nucleic acid and detect protein composition in food and environmental samples..

Leave a message
Name *
Email *
Whatsapp/Phone
Message *
Verification Code *
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.