• Touch screen xenon lamp double beam UV Vis spectrophotometer for lab spectral analysis
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometer for lab spectral analysis
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.

Touch screen xenon lamp double beam UV Vis spectrophotometer

No.LSP5-1101-XUV
The LSP5-1101-XUV is designed for laboratories in chemicalanalysis, life sciences, environmental testing, and industrialquality control. It is ideal for research institutions, educationalfacilities, and production labs that require precise andefficient visible spectrum analysis. Its intuitive touch-screeninterface enhances usability, making it suitable for bothroutine testing and complex analytical applications.
$9517.00
Model:
LSP5-1101-XUV
  • Touch screen xenon lamp double beam UV Vis spectrophotometer for lab spectral analysis
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Touch screen xenon lamp double beam UV Vis spectrophotometerIlabcarta Technology Co., Ltd.
  • Product Overview

  • Key Features

  • Parameter

  • Product Details

  • How to Choose

  • Packaging & delivery

  • Download

  • FAQ

  • Get a Quote

LSP5-1101-XUV touchscreen xenon lamp double beam UV Vis spectrophotometer targets chemical analysis labs, life science research, environmental testing, industrial QC, university research and teaching labs for scientists, lab analysts and quality control engineers. It eliminates common drawbacks of single-beam instruments (severe baseline drift), short-life traditional deuterium-tungsten lamps, complicated UI, limited storage, lack of GLP/GMP compliance, inconvenient data export and insufficient optional accessories.

Equipped with double-beam optical system with 1200 lines/mm grating and narrow 1.0nm spectral bandwidth, long-life xenon lamp and imported silicon photodiode detector, it covers full UV-Vis wavelength range 190–1100nm. The unit adopts 10.1-inch 1024*600 TFT capacitive color touch screen with intuitive Windows graphical interface and 1024M large built-in memory. It integrates full analysis modes: photometric measurement, quantitation, kinetics, spectrum scanning, DNA/protein assay and multi-wavelength test. Triple data output ports (USB storage, USB PC host, RS232 serial) support one-click Excel data export. Fully compliant with GLP/GMP standards, it delivers multi-level user authority management, complete operation logs and full data traceability. Standard configuration includes 10mm manual 4-cell holder, with optional expandable accessories such as auto cell changer, thermostatic autosampler, micro cell mount, reflection accessory and integrating sphere. The 1.0nm high-resolution bandwidth enables high-precision testing for micro and low-concentration samples, covering routine daily testing and advanced complex spectral research for teaching, industrial QC and academic labs.

.

  • Ultra-narrow 1.0nm spectral bandwidth: Matched with double-beam 1200 lines/mm grating, stray light ≤0.03%T and flat stable baseline, delivering higher resolution for micro and low-concentration samples ideal for precise academic quantitative research.
  • Integrated long-life xenon lamp: Replaces traditional dual deuterium-tungsten lamp set with drastically extended service life; socket-type lamp holder allows lamp replacement without optical calibration to cut long-term maintenance cost.
  • 10.1-inch high-definition capacitive color touch screen: 1024*600 Windows graphical interface with intuitive workflow, enabling untrained lab staff to finish calibration, scanning and data export quickly.
  • Six integrated analysis modes: Photometry, quantitation, kinetics, full spectrum scan, DNA/protein test and multi-wavelength simultaneous measurement, compatible with biochemical, environmental, chemical and pharmaceutical sample analysis.
  • 1024M massive internal memory: Stores thousands of spectra, calibration curves and raw lab data without frequent external USB backup.
  • Native GLP/GMP compliance framework: Multi-tier account permission, full operation logging and complete traceability for every data point to meet third-party audit standards for pharmaceutical & food export.
  • Multi-channel data output: Local USB storage, USB PC connection and RS232 serial port support one-click Excel export for report editing, graph plotting and archive storage.
  • Wide range of optional expandable accessories: Auto cell holder, thermostatic autosampler, micro cell mount, reflection accessory and integrating sphere for liquid, micro-volume, solid, constant-temperature reaction and diffuse reflection special sample measurement.
  • Imported silicon photodiode detector: Ultra-low noise 0.0005A with strong weak signal capture capacity for lower detection limit and excellent repeatability of trace micro samples.
  • Triple adjustable scanning speeds: High/Med/Low modes up to max 3000nm/min, balancing fast batch screening and high-precision slow fine scanning for different experimental scenarios.
Specifications LSP5-1101-XUV
Optical System Double Beam, Grating 1200 lines/mm
Wavelength Range 190-1100 nm
Spectral Bandwidth 1.0nm
Wavelength Accuracy ±0.1nm (at 656.1nm), ±0.3nm @all
Wavelength Repeatability ≤0.1nm
Photometric Accuracy 0.2%T(0~100%T), ±0.002A(0-0.5A), ±0.004A(0.5-1A)
Photometric Repeatability ≤0.15%T(0-100%T), 0.001A(0-0.5A), 0.002A(0.5-1A)
Photometric Range 0-200%T, -0.3~3A, -0.9999C(-0.9999F)
Stray Light ≤0.03%T @ 220,360nm
Stability ±0.0003A/h @500 nm
Baseline Flatness ±0.001A
Noise 0.0005A@500nm
Work Mode T, A, C, E
Scanning Speed Hi, Med, Low (Max.3000nm/min)
Wavelength Setting Auto
Display 10.1" TFT Colored Capacitive Touch Screen
Light Source Xenon lamp light
Detector Imported Silicon Photodiode
Cuvette Holder 10mm manual 4-cell holder
Output USB drive, USB host, RS232
Power Requirements AC 220V/50Hz or AC 110V/60Hz
Dimension[L×W×H] 570mm×440×210mm
Weight 20kg
Standard Accessories 10mm glass cuvette × 4, 10mm quartz cuvette × 2, Power cord, User's Manual, PC software


1.Power-on warm-up: Connect AC power and boot the unit, xenon lamp ignites automatically, full system self-check runs, sufficient warm-up eliminates optical baseline drift.
2.Experiment mode configuration: Select target analysis program via 10.1” touch screen (photometry/quantitation/kinetics/spectrum scan/DNA-protein/multi-wavelength), set scanning speed, wavelength range and data storage parameters.
3.Auto baseline correction: Fill blank reference solution into 10mm cuvette and place into 4-cell holder, run full auto baseline correction; double-beam optical path compensates background interference in real time.
4.Sample spectrum measurement: Insert test samples sequentially, start single-point measurement or continuous spectrum scan; the unit collects photometric and spectral data in real time with visualized curves and values displayed on screen.
5.Data storage & export: All spectra and calibration curves auto-saved to 1024M internal memory; plug in USB flash drive for one-click Excel export after experiment, or transmit data via USB/RS232 to matched PC software for graphing and test report generation.
6.Shutdown maintenance: Take out cuvettes, rinse with pure water and air-dry, turn off lamp and main power; disconnect power supply for long idle storage, wipe optical window to prevent dust accumulation.




  • Key Factors to Help You Pick the Right Model
  • Experiment precision grade distinction
  • Basic teaching, routine water & general chemical quantitation: LSP5-1102-XUV with 2.0nm bandwidth is acceptable; for micro, trace, life science DNA/protein and advanced material spectrum research, this 1.0nm narrow high-resolution model is preferred with superior detection resolution and repeatability.
  • Light source maintenance cost demand
  • High-volume continuous daily testing without frequent dual deuterium-tungsten lamp replacement: Integrated long-life xenon lamp drastically extends service life with socket-type no-calibration swap to cut equipment downtime.
  • Pharmaceutical & export testing compliance demand
  • Pharmaceutical factories, health food and export food third-party labs: Native full GLP/GMP audit trail system with complete operation log and data traceability passes overseas audit directly.
  • Special sample expandability demand
  • Solid, micro-volume liquid, constant-temperature kinetics and diffuse reflection material testing: Full optional expandable accessories supported without purchasing separate spectrophotometers.
  • Multi-user & novice operation scenario
  • University shared teaching labs and multi-operator QC workshops: 10.1-inch large Windows touch interface delivers simple workflow to lower staff training cost.
  • Matching Application Scenarios
  • LSP5-1101-XUV (1.0nm high-resolution xenon lamp double beam spectrophotometer) fits advanced research labs of university chemistry/biology/environment departments, third-party precision environmental testing institutes, pharmaceutical R&D & QC labs, biological reagent nucleic acid & protein quantitation, new material diffuse reflection spectrum analysis, micro trace pollutant detection and kinetic reaction mechanism research for research institutes.
  • Target Buyers: Key universities, research institutes, pharmaceutical manufacturers, third-party precision testing labs, new material R&D enterprises, provincial environmental monitoring centers, biotechnology companies.
  • Shockproof packaging solution: Multi-layer thick reinforced export wooden crate with custom integrated high-density shock-absorbing foam separating optical main unit, glass cuvettes, power cord and software CD to avoid breakage & collision during long sea & land transit; thickened solid wooden crate as default for bulk overseas orders.
  • Full set package contents: LSP5-1101-XUV spectrophotometer main unit, 4 pcs 10mm glass cuvette, 2 pcs 10mm quartz cuvette, AC power cord, printed factory user manual, PC spectrum analysis software CD, factory quality inspection certificate.
  • Reference package dimension & weight: Single full-set outer crate 62×49×28cm, gross weight 24kg per unit.
  • Lead time: In-stock standard models ship within 3–10 working days; custom wavelength range, full expandable accessory bundle and customized software UI orders take 15–30 working days.
  • Logistics options: Sea freight, air freight and full-truck land transport available, dedicated logistics line for bulk overseas export of large precision lab analytical instruments.

Selling Units

Single item

Package size perbatch

60*48*37cm

Gross weight perbatch

16.8kg

 

Name Qty.
Main unit (SP-XUV5101 UV-Vis Spectrophotometer) 1
1cm Standard quartz cuvette (2 pcs) 1 set
Cuvette holder (fixed, 1cm) 1
Power cord 1
USB cable 1
Operating Manual 1
Certificate of Quality 1
Contact customer service to receive full documents: Integrated complete technical datasheet, full instrument calibration & operation manual, dimension drawings, product brochure, factory inspection report and GLP/GMP compliance audit document for university lab tender filing and pharmaceutical precision testing project archive.

  1. What is the core difference between LSP5-1101-XUV and LSP3 double-beam series?
    LSP3 adopts deuterium & tungsten combined light source, while LSP5-1101-XUV is equipped with extra-long service life xenon lamp light source, delivering continuous spectrum without breakpoints and uniform energy across full wavelength range. Both feature double-beam real-time baseline compensation, 1.0nm ultra-narrow bandwidth, identical optical detection indexes, 10.1-inch touch screen, triple output ports, overall dimension and net weight. Xenon lamp avoids frequent replacement and drastically cuts long-term consumable maintenance cost, ideal for all-day uninterrupted batch scanning and long-duration kinetic experiments.
  2. Does xenon lamp need frequent replacement, is maintenance cost high?
    The dedicated long-life xenon lamp has far longer service life than traditional deuterium-tungsten combined light sources, reducing frequent lamp replacement and optical path calibration steps. Consumable and labor maintenance cost is lower for long-term mass testing workflows without repeated optical debugging.
  3. What is the full wavelength range and optical architecture?
    Double-beam optical path matched with 1200 lines/mm grating, full UV-NIR coverage 190–1100nm with 1.0nm ultra-narrow bandwidth. Double-beam design realizes full-process real-time automatic baseline compensation with negligible drift during long-time scanning.
  4. How large is the local storage capacity, will experimental data be lost after power cut?
    Built-in massive 1024M local memory for mass storage of curves and test data. All curves, operation logs and raw data are auto-saved in real time during unexpected power failure, complete experimental records can be directly recalled after power recovery without full re-calibration and re-test.
  5. Does it meet GLP/GMP audit compliance requirements?
    Natively supports complete GLP/GMP system, hierarchical independent user accounts, operation passwords, full-run logs and full traceable export of raw data, fully matching inspection standards of pharmaceutical factories and third-party testing institutes.
  6. What test programs are supported, can it run long-duration kinetics and DNA/protein testing?
    Pre-installed programs include photometric measurement, quantitative calibration, full-wavelength scan, multi-wavelength simultaneous detection, long-time kinetics and dedicated nucleic acid protein analysis. Three scan speed grades with max 3000nm/min scan rate. The combination of double-beam design and stable xenon light source is specially optimized for multi-hour uninterrupted monitoring.
  7. What sample holder comes as standard, what consumables are compatible?
    Standard 10mm manual 4-position cuvette holder compatible with general 10mm glass and quartz cuvettes. Optional micro rack supports micro & semi-micro specimen testing.
  8. How many data output ports are equipped, what are their respective functions?
    Triple communication outputs: ①USB flash drive: offline storage, data export, local firmware upgrade; ②USB host: connect supporting PC software for batch spectrum processing; ③RS232 serial port: link automatic production lines and industrial control equipment.
  9. How many scan speed grades are available, what is the maximum scan rate?
    Three fully automatic adjustable scan grades (High/Med/Low), maximum scan speed up to 3000nm/min, drastically shortening full-band spectrum acquisition time and improving batch sample testing efficiency.
  10. What are the core optical indexes (stray light, noise, photometric stability)?
    Stray light ≤0.03%T @220/360nm; noise 0.0005A @500nm; photometric stability ±0.0003A/h after 2h preheat. Combined with double-beam real-time baseline compensation, long-run baseline drift control achieves excellent performance.
  11. What is the display specification, is operation difficult?
    10.1-inch 1024×600 color capacitive touch large screen with Windows graphical visual interface, full-touch simple operation, new users can quickly edit all types of experimental programs.
  12. Does the wide voltage fit overseas 110V labs?
    Auto-adaptive wide voltage AC 110V/60Hz & AC 220V/50Hz, labs in Europe, America and Southeast Asia can operate directly without external voltage transformer.
  13. What are the overall dimension and net weight of the unit?
    Overall dimension 570mm×440mm×210mm, net weight 20kg, heavy-duty optical base with low running vibration and superior long-term optical stability.
  14. What optional extended accessories are available for special sample testing?
    Optional accessories: automatic thermostatic cell holder, fully automatic sampler, adjustable micro cell holder, reflection integrating sphere, variable optical path solid sample rack, matching special experiments including temperature-controlled kinetics, solid powder and high-throughput microplate testing.
  15. What type of labs is this unit suitable for procurement?
    New drug cutting-edge R&D institutes, national key university research labs, pharmaceutical factories with all-day uninterrupted batch testing, high-end environmental trace analysis platforms requiring ultra-long continuous kinetics and high-precision research workflows with low-maintenance long-life light source.

  • Provide order quantity, destination country and optional expandable accessories / custom wavelength demand to receive tiered bulk discount quotation
  • Free customized spectrum analysis matching scheme for research / pharmaceutical / precision environmental labs, official PI issued within 24 hours
  • Exclusive discounted pricing available for bulk procurement from universities, pharmaceutical manufacturers and third-party precision testing institutes
Applications 应用场景模块

Applications

Applications

Supporting diverse laboratory and industrial environments with practical instrument solutions.

Research Laboratories

Research Laboratories

Conduct SDS-PAGE protein separation, nucleic acid electrophoresis and molecular specimen analysis for life science research..

Universities and Education

Universities & Education

Complete protein & gene electrophoresis experiments for biotech, biology and chemistry course training.

Pharmaceutical and Chemical

Pharmaceutical & Chemical

Analyze target protein, separate biological ingredients and test biopharmaceutical sample purity.

Food Environmental and Industrial Testing

Food, Environmental & Industrial Testing

Identify microbial nucleic acid and detect protein composition in food and environmental samples..

Leave a message
Name *
Email *
Whatsapp/Phone
Message *
Verification Code *
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.