• UV‑visible spectrophotometer for laboratory qualitative quantitative spectral analysis
  • UV-visible spectrophotometerIlabcarta Technology Co., Ltd.
  • UV-visible spectrophotometerIlabcarta Technology Co., Ltd.
  • UV-visible spectrophotometerIlabcarta Technology Co., Ltd.
  • UV-visible spectrophotometerIlabcarta Technology Co., Ltd.
  • UV‑visible spectrophotometer for laboratory qualitative quantitative spectral analysis
  • UV-visible spectrophotometerIlabcarta Technology Co., Ltd.
  • UV-visible spectrophotometerIlabcarta Technology Co., Ltd.
  • UV-visible spectrophotometerIlabcarta Technology Co., Ltd.
  • UV-visible spectrophotometerIlabcarta Technology Co., Ltd.

UV-visible spectrophotometer

No.LSP-1004-V/LSP-1004-UV LSP-1102-V/LSP-1102-UV
Our spectrophotometer measures sample absorbance and transmittance for qualitative and quantitative analysis. It supports kinetics tests, protein and nucleic acid quantification, and is widely applied in medical care, clinical testing, biochemistry, petrochemicals, environmental monitoring, food inspection, as well as university teaching and experiments.
$1238.20
Model:
LSP-1004-V
LSP-1004-UV
LSP-1102-UV
LSP-1102-V
  • UV‑visible spectrophotometer for laboratory qualitative quantitative spectral analysis
  • UV-visible spectrophotometerIlabcarta Technology Co., Ltd.
  • UV-visible spectrophotometerIlabcarta Technology Co., Ltd.
  • UV-visible spectrophotometerIlabcarta Technology Co., Ltd.
  • UV-visible spectrophotometerIlabcarta Technology Co., Ltd.
  • Product Overview

  • Key Features

  • Parameter

  • Product Details

  • How to Choose

  • Packaging & delivery

  • Download

  • FAQ

  • Get a Quote

LSP-1004 / LSP-1102 series are entry-level single-beam spectrophotometers with dot matrix LCD, including visible light version (V) and UV-visible version (UV), with two spectral bandwidth options: 4.0nm and 2.0nm. They target basic teaching labs of colleges, routine industrial QC of small factories, grassroots environmental monitoring stations and testing rooms of small chemical/food enterprises for student trainees, basic lab technicians and low-budget daily QC operators. It solves pain points of old simple spectrophotometers such as limited storage capacity, lack of automatic wavelength calibration, non-intelligent light source switching, no power-off data protection, poor compatibility of optional accessories and difficulty in purchasing storage-enabled instruments with tight budgets.
Adopting single-beam optical system with 1200 lines/mm grating, the series provides 4.0nm wide bandwidth (1004 series) and 2.0nm standard bandwidth (1102 series). Light source options include pure tungsten lamp for visible range, and tungsten + deuterium dual lamp for full UV-Vis range with intelligent automatic switching to extend lamp service life. Equipped with dot matrix LCD, the unit supports local storage of 128 calibration curves and 4000 test data sets, with real-time data saving to avoid loss during sudden power failure. It integrates six basic analysis modes: photometric measurement, quantitative assay, kinetics scanning, spectrum scan, basic DNA/protein quantification and multi-wavelength test. Dual output ports (USB & parallel) support connection with printers and PC software, alongside automatic wavelength calibration and dark current correction. Standard configuration includes 1cm manual 4-position sample holder, fully compatible with auto cell holder, thermostatic autosampler, micro cell mount, reflection accessory, integrating sphere and other expandable accessories. Compact and lightweight (11kg / 14.6kg, dimension 475×360×225mm), it features ultra-low procurement cost, ideal for entry-level labs with tight budgets only undertaking routine batch screening and basic teaching training
  • Dual bandwidth & dual spectrum versions available: 4.0nm economical wide bandwidth (LSP-1004), 2.0nm standard universal bandwidth (LSP-1102); two light source configurations (visible only / full UV-Vis) to cover pure visible and full-spectrum testing demands, flexibly matching budget and precision requirements.

  • Japan imported tungsten / deuterium-tungsten combined light source: Original HYBEC tungsten lamp, Milaras deuterium lamp with intelligent automatic switching and idle lamp power-off to greatly extend lamp service life and cut consumable replacement cost.

  • Dot matrix LCD simple interactive screen: Intuitive interface allows untrained students and grassroots technicians to operate quickly, with low failure rate and easy maintenance.

  • Large-capacity local storage: Stores up to 128 calibration curves and 4000 test data sets with real-time auto-save to prevent data loss during sudden power outage.

  • Fully automatic calibration functions: Built-in auto wavelength calibration and dark current correction programs eliminate manual baseline adjustment and reduce human operation error.

  • Intelligent light source energy-saving system: The instrument automatically switches the corresponding lamp according to test wavelength and powers off idle lamps to effectively extend deuterium & tungsten lamp lifespan.

  • Six integrated basic analysis programs: Photometry, quantitation, kinetics, spectrum scanning, basic DNA/protein test and multi-wavelength analysis, covering all basic experiments for teaching training and routine production batch screening.

  • Series universal optional accessories: Fully compatible with auto cell holder, thermostatic autosampler, adjustable micro cell mount, reflection accessory, integrating sphere and more, sharing consumables with full spectrophotometer series with no full accessory replacement needed for later upgrade.

  • Dual output ports (USB + Parallel): Direct connection with printers for test report printing, or matched PC software for extended functions including wavelength scan, kinetics, multi-wavelength and DNA/protein analysis.

  • Compact lightweight body: Dimension 475×360×225mm, net weight only 11kg / 14.6kg, occupying minimal lab bench space and easy to transport & place, perfect for small testing rooms and classroom workbenches.

Specifications LSP-1004-V LSP-1004-UV LSP-1102-V LSP-1102-UV
Optical System Single Beam Single Beam Single Beam Single Beam
Light Source Tungsten Lamp(Japan HYBEC) Tungsten Lamp(Japan HYBEC)|Deuterium Lamp(Milaras) Tungsten Lamp(Japan HYBEC) Tungsten Lamp(Japan HYBEC)|Deuterium Lamp(Milaras)
Spectral Bandwidth 4.0nm 4.0nm 2.0nm 2.0nm
Wavelength Range 325-1000nm 200-1000nm 320-1100nm 190-1100nm
Wavelength Accuracy ±2nm ±2nm ±0.5nm ±0.5nm
Wavelength Repeatability ≤1nm ≤1nm ≤0.3nm ≤0.3nm
Photometric Range -0.3-3.0A, 0-200%T -0.3-3.0A, 0-200%T -0.3-3.0A, 0-200%T -0.3-3.0A, 0-200%T
Photometric Accuracy ±0.003 A @ 0.5 A,±0.006 A @ 1.0 A,±0.5%T @ 100%T ±0.003 A @ 0.5 A,±0.006 A @ 1.0 A,±0.5%T @ 100%T ±0.002 A @ 0.5 A,±0.004 A @ 1.0 A,±0.3%T @ 100%T ±0.002 A @ 0.5 A,±0.004 A @ 1.0 A,±0.3%T @ 100%T
Photometric Repeatability ≤0.0015A @ 0.5 A,≤0.003 A @ 1.0 A,≤0.25%T @ 100%T ≤0.0015A @ 0.5 A,≤0.003 A @ 1.0 A,≤0.25%T @ 100%T ≤0.001A@ 0.5 A,≤0.002 A @ 1.0 A,≤0.15%T @ 100%T ≤0.001A@ 0.5 A,≤0.002 A @ 1.0 A,≤0.15%T @ 100%T
Stability ≤0.002 A/h @ 500 nm(after preheat 2 hours) ≤0.002 A/h @ 500 nm(after preheat 2 hours) ≤0.002 A/h @ 500 nm(after preheat 2 hours) ≤0.002 A/h @ 500 nm(after preheat 2 hours)
Stray Light ≤0.2%T @ 360nm ≤0.2%T @ 360nm ≤0.05%T @ 360nm ≤0.05%T @ 220&360nm
Sample Compartment Manual 4-position 1cm holder(standard for single beam) Manual 4-position 1cm holder(standard for single beam) Manual 4-position 1cm holder(standard for single beam) Manual 4-position 1cm holder(standard for single beam)
Display Dot Matrix LCD Dot Matrix LCD Dot Matrix LCD Dot Matrix LCD
Output USB Port&Parallel Port ( Printer) USB Port&Parallel Port ( Printer) USB Port&Parallel Port ( Printer) USB Port&Parallel Port ( Printer)
Power Requirements 110/220VAC,50/60Hz,80W 110/220VAC,50/60Hz,120W 110/220VAC,50/60Hz,80W 110/220VAC,50/60Hz,120W
Dimension[L×W×H] 475x360x225mm 475x360x225mm 475x360x225mm 475x360x225mm
Weight 11kg 14.6kg 11kg 14.6kg
  • Power-on warm-up: Connect universal 110/220V power supply and boot the unit, the corresponding lamp for test wavelength lights up automatically, full system self-check runs, 2-hour preheat delivers stable baseline to eliminate photometric drift.
  • Experiment mode selection: Select target program on dot matrix LCD (photometry/quantitation/kinetics/spectrum scan/DNA-protein test/multi-wavelength), set scanning speed, target wavelength and storage parameters.
  • Auto baseline correction: Place blank reference 1cm cuvette, one-click launch auto wavelength calibration + dark current correction; the unit completes background compensation automatically with no manual zero adjustment required.
  • Sample measurement: Insert test samples sequentially and run single-point absorbance test or continuous spectrum scan; transmittance, absorbance and concentration values display in real time with synchronous auto data storage.
  • Data output: After testing, print hard-copy reports via parallel port printer, or transmit data to PC software via USB for wavelength scanning, kinetic graph plotting and batch Excel data export.
  • Shutdown maintenance: Take out cuvettes, rinse with pure water and air-dry; the unit powers off idle lamps automatically before main power cut. Wipe sample compartment and optical window for long-term storage to avoid dust impairing test precision.

. Bandwidth & Precision Tier Selection

  1. LSP-1004 series (4.0nm bandwidth): Economical entry model for college basic teaching, rough testing of high-concentration samples and small factories with ultra-tight budgets; wavelength accuracy ±2nm, suitable for labs with no micro low-concentration testing demands.
  2. LSP-1102 series (2.0nm bandwidth): Standard universal precision with ±0.5nm wavelength accuracy and lower stray light, balancing teaching and routine batch QC for chemical, food and water samples, the mainstream model with comprehensive cost performance.

2. Wavelength Range Selection (V=Visible only / UV=Full UV-Vis)

  1. -V Visible version: 320/325–1000nm with single tungsten lamp, lower cost, only for colored substance testing in visible range, select if no nucleic acid or UV pollutant analysis required.
  2. -UV UV-Vis version: 200/190–1000/1100nm with deuterium-tungsten dual lamp covering UV band, supports DNA/RNA, micro organic and heavy metal UV detection, preferred for teaching and small R&D labs.

3. Budget & Maintenance Comparison

  1. Net weight 11kg (-V visible model), 14.6kg (-UV UV model); UV version carries built-in deuterium lamp with higher power and slightly heavier body.
  2. All series share identical accessories; optional holders and cuvettes are interchangeable with no full consumable replacement needed for later upgrade.
  3. All models support auto light source switching, power-off data storage and full auto calibration with basic compliance recording functions to satisfy internal audit requirements of colleges and small factories.

Matching Application Scenarios (9 Standard Categories)

  1. Research Laboratories: Basic spectrum mechanism, simple quantitation of high-concentration substances (1004); routine analysis of low-concentration raw materials (1102 UV)
  2. Universities & Education: Basic chemistry & biology training for colleges & vocational schools (all series compatible)
  3. Pharmaceutical & Chemical: Crude raw material test of small chemical plants, routine content screening of general preparations (1102 UV)
  4. Food, Environmental & Industrial Testing: Water quality test for township water plants, raw material QC of small food factories, routine grassroots environmental monitoring
  5. Medical & Healthcare: Rough visible-range screening of biological samples for grassroots clinics (V model); basic nucleic acid & protein quantitation (UV model)
  6. Semiconductor & Electronics: Rough purity detection of cleaning fluid
  7. Textile & Leather: Simple determination of dye concentration for small printing & dyeing factories
  8. Automotive: Routine screening of general coolant and lubricant
  9. Aerospace: Simple purity test of basic solvents (not for precision micro R&D)
  • Shockproof packaging: Thickened export wooden crate with integrated shock-absorbing foam separating optical main unit, cuvettes, power cord and software CD to avoid breakage during short/long sea & land transit; thickened crate as default for bulk orders.

  • Full package contents: Spectrophotometer main unit, matched glass/quartz cuvettes, AC wide-voltage power cord, printed user manual, PC spectrum analysis software CD, factory quality inspection certificate.

  • Package dimension & weight: Outer crate approx 520×410×310mm; net weight 11kg/14.6kg, gross weight 16kg/19kg.

  • Lead time rule: In-stock standard models ship within 3–10 working days; custom wavelength range, full accessory bundle and customized software UI orders take 15–30 working days.

  • Logistics options: Sea freight, air freight and LTL road transport available, dedicated logistics line for bulk export of economical teaching lab instruments.

Selling Units

Single item

Package size perbatch

60*48*37cm

Gross weight perbatch

16.8kg

 

Name

Qty

Main Unit

1

Power Adapter

1

User Manual

1

Certificate of Conformity

1

Warranty Card

1

Dust Cover

1

Sample Cell Holder (10mm, 4‑cell)

1

Quartz Cuvette (1cm)

2

Glass Cuvette (1cm)

2

USB Data Cable

1

RS232 Data Cable

1

Software CD / USB Drive

1

Contact customer service to receive full documents: 4-model comparison datasheet, full operation & calibration manual for dot matrix spectrophotometer, dimension drawings, product brochure, factory inspection report and PC software guide for tender archive of vocational school and small factory lab equipment.

  • What are core differences between LSP-1004 and LSP-1102 series?
    ①Spectral bandwidth: 1004 series standard 4.0nm; 1102 series narrow high-resolution 2.0nm with overall superior wavelength accuracy, repeatability, stray light and photometric stability, outstanding for trace low-concentration samples.
    ②Wavelength coverage: V visible models 1004:325–1000nm, 1102:320–1100nm; UV dual-light models 1004 cut-off 200nm, 1102 extends down to 190nm for wider short-wave UV range.
    ③Photometric error: The 1102 series delivers better absorbance & transmittance precision and repeatability.
    ④Stray light: 1102-V ≤0.05%T vs 1004-V ≤0.2%T, lower stray light reduces background interference for trace specimens.
    ⑤Positioning: 1004 for basic teaching & routine standard testing; 1102 for R&D, trace nucleic acid and high-precision drug gradient trials.
  • What do suffix V and UV stand for in light source, how to select?
    -V: Only Japan HYBEC tungsten lamp, visible band starting at 325/320nm, for colored substance & visible protein quantification without UV measurement demand.
    -UV: Dual tungsten + Milaras deuterium lamp covering full UV-NIR from 190/200nm; mandatory selection for DNA/RNA nucleic acid, UV-absorbing drug and organic solvent testing.
  • How many standard curves and test data can be stored, will data be lost after power cut?
    Up to 128 complete standard curves and 4000 raw test records; all data & curves are auto-saved in real time during power failure, files can be recalled directly after power recovery without re-calibration or re-test.
  • Does the instrument support automatic wavelength calibration, is manual baseline correction required?
    Built-in auto wavelength & dark current calibration program; one-touch baseline zeroing by loading blank reference before each run, no manual wavelength adjustment needed.
  • Can light sources switch automatically to extend bulb service life?
    UV dual-light models auto-switch tungsten / deuterium lamp according to set wavelength and turn off idle lamp outside corresponding band to drastically reduce bulb wear and extend lifespan; single V tungsten lamp model has no switching logic.
  • What optional extended accessories are available for special sample testing?
    Optional attachments: auto temperature-controlled cell holder, 8-strip / 96-well plate tube rack, solid reflectance sample holder, variable long optical path components, thin film rack for temperature-controlled kinetics, solid powder and high-throughput microplate workflows.
  • What analysis functions are integrated in matching PC software?
    Multi-function single interface: full-range wavelength scan, continuous time kinetics monitoring, simultaneous multi-wavelength fixed-point detection, DNA/RNA/protein quantification analysis; customizable expandable experimental workflows with real-time spectrum data tracking.
  • What sample holder comes as standard, what consumables are compatible?
    Manual 4-position standard 1cm cuvette holder; compatible with standard 1cm glass/quartz cuvettes, 0.2mL single PCR tubes, 8-strip tubes and three types of skirted 96-well microplates.
  • How long is the required preheating to reach photometric stability, what is the stability index?
    Standard 2-hour preheating; photometric stability ≤0.002A/h @500nm, low drift during long continuous scanning with excellent repeatability for parallel experiments.
  • What output ports are equipped, can printers and U-disk be connected for data export?
    Dual USB + parallel printer ports available; U-disk stores & exports all curves and test records, also supports local firmware upgrade via flash drive; parallel port connects printer directly for real-time spectrum printout.
  • Does the wide voltage fit overseas 110V labs?
    Auto-adaptive wide voltage 110/220V 50/60Hz, European, American and Southeast Asian overseas labs can operate directly without external voltage transformer.
  • Power consumption and net weight difference between single V lamp and dual UV lamp versions?
    Single tungsten V model: 80W power, 11kg net weight; dual tungsten-deuterium UV model: 120W power, 14.6kg net weight; all four models share identical overall dimension 475×360×225mm.
  • Is the stray light gap obvious between two series, what impact on trace samples?
    1004 series stray light ≤0.2%T@360nm; 1102 series ≤0.05%T (UV models controlled at both 220nm & 360nm). Lower stray light minimizes background interference of low-concentration trace samples and improves quantitative accuracy.
  • Does it support kinetics and Touchdown gradient wavelength scan experiments?
    Pre-set built-in program modes available for long-duration time kinetics and Touchdown gradient wavelength scanning, suitable for multi-stage continuous collection of nucleic acid and protein samples.
  • What type of labs is each model suitable for procurement?
    LSP-1004-V: University teaching labs, basic routine visible light quantification;
    LSP-1004-UV: Small & medium food, environmental and general pharmaceutical labs for routine full-band testing without ultra-high precision demand;
    LSP-1102-V: Biochemical labs requiring high-precision trace visible protein analysis;
    LSP-1102-UV: Research institutes, new drug R&D, nucleic acid quantification and low-concentration drug UV gradient scientific trials.

  • Specify model (1004-V/1004-UV/1102-UV/1102-V), order quantity, destination country and optional accessories to receive tiered bulk discount quotation
  • Free customized lab scheme for university teaching & small industrial routine testing labs, official PI issued within 24 hours
  • Exclusive discounted pricing available for bulk procurement from vocational schools, small food & environmental testing factories
Applications 应用场景模块

Applications

Applications

Supporting diverse laboratory and industrial environments with practical instrument solutions.

Research Laboratories

Research Laboratories

Conduct SDS-PAGE protein separation, nucleic acid electrophoresis and molecular specimen analysis for life science research..

Universities and Education

Universities & Education

Complete protein & gene electrophoresis experiments for biotech, biology and chemistry course training.

Pharmaceutical and Chemical

Pharmaceutical & Chemical

Analyze target protein, separate biological ingredients and test biopharmaceutical sample purity.

Food Environmental and Industrial Testing

Food, Environmental & Industrial Testing

Identify microbial nucleic acid and detect protein composition in food and environmental samples..

Leave a message
Name *
Email *
Whatsapp/Phone
Message *
Verification Code *
Verification Code
We use Cookie to improve your online experience. By continuing browsing this website, we assume you agree our use of Cookie.